摘要
Surface blood compatibility of ion beam and plasma treatment on polyetherurethane has been studied.O^(+)implantation was performed at 80keV with various doses.O_(2) plasma treatment was carried out at 100 W with various exposure times.The results indicated that surface anticogulability was enhanced in varying degrees and anticalcific behavior was not decreased.X-ray photoelectron spectroscopy and electron spin resonance analysis showed that the two methods not only broke some chemical bonds,but also produced some new N-O and C-O bonds and radicals in the surface,which affected the surface biomedical behavior.
作者
LI De-jun
CUI Fu-zhai
FENG Qing-ling
ZHAO Jie
李德军;崔福斋;冯庆玲;赵杰(Department of Materials Science and Engineering,Tsinghua University,Beijing 100084;Department of Physics,Tianjin Normal University,Tianjin 300074)
基金
Supported by the National Natural Science Foundation of China under Grant No.19305006
the Natural Science Foundation of Tianjin
by the Ion Beam Laboratory,Shanghai Institute of Metallurgy,Chinese Academy of Sciences.