Determination of 7 Indictor Polychlorinated Biphenyls (PCBs) Residues in Porphyra by Ultrasonic Extraction and Gas Chromatography (GC)

Determination of 7 Indictor Polychlorinated Biphenyls (PCBs) Residues in Porphyra by Ultrasonic Extraction and Gas Chromatography (GC)
在线阅读 下载PDF
导出
摘要 A method was developed for determination of 7 indictors the polychlorinated biphenyls (PCBs) residues in porphyra by gas chromatography (GC) with electron capture detector (ECD). The PCBs were extracted with hexane/methylene chloride (1:1, v/v) by ultrasonic extraction and the samples were cleaned up by concentrated sulfuric acid and Alumina-N solid phase extraction cartridge. The analytes were quantified by an internal standard method. Under optimal experimental conditions, good linearity was observed in the range of 5 - 200 ng/mL and the correlation coefficients were 0.9994 - 0.9998. The limit of quantitation (LOQ) for target analytes ranged from 6.0 to 10.0 μg/kg. At the spiked levels of 10, 50, 100 μg/kg, the average recoveries ranged from 90.9% to 102% with the relative standard deviations 2.12% - 6.32%. The result showed that the proposed method was rapid, and could be used for the determination of the PCBs in porphyra. A method was developed for determination of 7 indictors the polychlorinated biphenyls (PCBs) residues in porphyra by gas chromatography (GC) with electron capture detector (ECD). The PCBs were extracted with hexane/methylene chloride (1:1, v/v) by ultrasonic extraction and the samples were cleaned up by concentrated sulfuric acid and Alumina-N solid phase extraction cartridge. The analytes were quantified by an internal standard method. Under optimal experimental conditions, good linearity was observed in the range of 5 - 200 ng/mL and the correlation coefficients were 0.9994 - 0.9998. The limit of quantitation (LOQ) for target analytes ranged from 6.0 to 10.0 μg/kg. At the spiked levels of 10, 50, 100 μg/kg, the average recoveries ranged from 90.9% to 102% with the relative standard deviations 2.12% - 6.32%. The result showed that the proposed method was rapid, and could be used for the determination of the PCBs in porphyra.
作者 Liangliang Tian Feng Han Youqiong Cai Cong Kong Yongfu Shi Yuan Wang Guangxin Yang Qianyun Zhan Dongmei Huang Liangliang Tian;Feng Han;Youqiong Cai;Cong Kong;Yongfu Shi;Yuan Wang;Guangxin Yang;Qianyun Zhan;Dongmei Huang(Aquatic Product Quality Inspection and Test Center (Shanghai), Ministry of Agriculture of China, East China Sea Fisheries Research Institute, Shanghai, China;College of Food Science and Engineering, Ocean University of China, Qingdao, China)
出处 《Journal of Agricultural Chemistry and Environment》 2016年第1期1-5,共5页 农业化学和环境(英文)
关键词 Polychlorinated Biphenyls (PCBs) PORPHYRA Ultrasonic Extraction Gas Chromatography (GC) Polychlorinated Biphenyls (PCBs) Porphyra Ultrasonic Extraction Gas Chromatography (GC)
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部