期刊文献+

A Novel Technique to Validate Dosimetry for Single-Isocenter Multiple-Target VMAT Stereotactic Radiosurgery 被引量:1

A Novel Technique to Validate Dosimetry for Single-Isocenter Multiple-Target VMAT Stereotactic Radiosurgery
在线阅读 下载PDF
导出
摘要 <div style="text-align:justify;"> Each year, 170,000 cancer patients in the United States develop brain metastases. Many of them present with multiple small lesions. Historically, Linac-based stereotactic radiosurgery (SRS) was used to treat single solitary brain metastasis with a diameter of less than 3.0 cm, while whole brain radiation therapy (WBRT) was used to treat multiple brain metastases mainly as palliative therapy. Evidence-based practices reveal that WBRT results in poor treatment outcomes, with high local recurrence rates, decreased cognitive function, and even the onset of dementia. Recently, volumetric modulated arc therapy (VMAT) SRS has been tested as an alternative treatment to WBRT. Owing to its inherent complexity and high risk, it is imperative to perform rigorous testing prior to its clinical implementation. In this paper, we present a novel technique for dosimetry validation of VMAT SRS. </div> <div style="text-align:justify;"> Each year, 170,000 cancer patients in the United States develop brain metastases. Many of them present with multiple small lesions. Historically, Linac-based stereotactic radiosurgery (SRS) was used to treat single solitary brain metastasis with a diameter of less than 3.0 cm, while whole brain radiation therapy (WBRT) was used to treat multiple brain metastases mainly as palliative therapy. Evidence-based practices reveal that WBRT results in poor treatment outcomes, with high local recurrence rates, decreased cognitive function, and even the onset of dementia. Recently, volumetric modulated arc therapy (VMAT) SRS has been tested as an alternative treatment to WBRT. Owing to its inherent complexity and high risk, it is imperative to perform rigorous testing prior to its clinical implementation. In this paper, we present a novel technique for dosimetry validation of VMAT SRS. </div>
作者 Yulin Song Miao Zhang Laszlo Voros Xiaoli Tang Ziad Saleh Weixing Cai Jeho Jeong Boris Mueller Borys Mychalczak Yulin Song;Miao Zhang;Laszlo Voros;Xiaoli Tang;Ziad Saleh;Weixing Cai;Jeho Jeong;Boris Mueller;Borys Mychalczak(Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, USA;Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, USA)
出处 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2021年第2期59-68,共10页 医学物理学、临床工程、放射肿瘤学(英文)
关键词 Brain Metastasis VMAT SRS WBRT Film Dosimetry Brain Metastasis VMAT SRS WBRT Film Dosimetry
  • 相关文献

同被引文献1

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部