期刊文献+

Clinical significance of magnetic resonance cholangiopancreatography utilizing half-Fourier acquisition single-shot fast spin-echo in diagnosing bile duct diseases 被引量:1

Clinical significance of magnetic resonance cholangiopancreatography utilizing half-Fourier acquisition single-shot fast spin-echo in diagnosing bile duct diseases
在线阅读 下载PDF
导出
摘要 Objective: To investigate the clinical significance of magnetic resonance cholangiopancreatography (MRCP) utilizing half-Fourier acquisition single-shot fast spin-echo (HASTE) in the diagnosis of bile duct diseases. Methods: Forty-three patients with obstructive jaundice and 4 without were enrolled in this study. The underlying diseases included bile duct calculi ( 13 cases) , chronic cholangitis ( 14 cases) malignant tumors (18 cases) and congenital biliary cysts (2 cases). All patients underwent examinations with magnetic resonance imaging (MRI) and MRCP, and 39 were also examined with B-type ultrasonography, 33 with CT and 25 with ERCP and PTC. Three-dimensional image reconstruction was performed using volume-rendered technique ( VRE) on the basis of the data obtained by MRCP. Results: The biliary calculi were displayed as circular filling defects in MRCP images, with the proximal end of dilated bile duct taking the form of the mouth of a cup. The bile duct of patients with chronic cholangitis showed distal end dilation and thinner proximal end without discontinuity. Interception of the bile ducts was most frequent (72. 2% ) in cases of malignant bile duct obstruction, in which the ducts may also be mastoid or resembling rat tails. 72. 2% of the cases had severe dilation of the bile ducts, which occur in only 16. 0% of the benign cases, with significant difference between them (P <0. 01) . In images of intrahepatic biliary cyst, intrahepatic duct dilated in the shape of a bursa in connection with the duct. By MRCP, 20 malignant obstructions of the bile ducts were identified with 2 misdiagnoses, and in 25 cases of benign obstructions identified by MRCP, only 1 misdiagnoses occurred. Thus MRCP had the sensitivity, specificity and accuracy of 90.0% , 96.3% and 93.6% respectively in discriminating benign and malignant diseases of the bile ducts, showing a total diagnostic accuracy of 94. 0% that was similar to that of ERCP (92.0% ) but significantly higher than those of both CT (75. 0% ) and B-type ultrasonic examination (74. 0% ). Conclusion: In diagnosing obstructive jaundice, HASTE MRCP is similar to ERCP but better than CT and B-type ultrasonography , with the merits of fast imaging and high resolution as an ideal sequence for MRCP imaging. Objective: To investigate the clinical significance of magnetic resonance cholangiopancreatography(MRCP) utilizing half-Fourier acquisition single-shot fast spin-echo (HASTE) in the diagnosis of bile duct diseases.Methods: Forty-three patients with obstructive jaundice and 4 without were enrolled in this study. The underlying diseases included bile duct calculi ( 13 cases), chronic cholangitis ( 14 cases) malignant tumors ( 18 cases) and congenital biliary cysts (2 cases). All patients underwent examinations with magnetic resonance imaging (MRI) and MRCP,and 39 were also examined with B-type ultrasonography, 33 with CT and 25 with ERCP and PTC. Three-dimensional image reconstruction was performed using volume-rendered technique (VRE) on the basis of the data obtained by MRCP. Results: The biliary calculi were displayed as circular filling defects in MRCP images, with the proximal end of dilated bile duct taking the form of the mouth of a cup. The bile duct of patients with chronic cholangitis showed distal end dilation and thinner proximal end without discontinuity. Interception of the bile ducts was most frequent(72.2%) in cases of malignant bile duct obstruction, in which the ducts may also be mastoid or resembling rat tails.72.2% of the cases had severe dilation of the bile ducts, which occur in only 16.0% of the benign cases, with significant difference between them ( P < O. O1 ). In images of intrahepatic biliary cyst, intmhepatic duct dilated in the shape of a bursa in connection with the duct. By MRCP, 20 malignant obstructions of the bile ducts were identified with 2 misdiagnoses, and in 25 cases of benign obstructions identified by MRCP, only 1 misdiagnoses occurred. Thus MRCP had the sensitivity, specificity and accuracy of 90.0%, 96.3% and 93.6% respectively in discriminating benign andmalignant diseases of the bile ducts, showing a total diagnostic accuracy of 94.0% that was similar to that of ERCP(92.0%) but significantly higher than those of both CT ( 75.0% ) and B-type ultrasonic examination ( 74.0% ).Conclusion: In diagnosing obstructive jaundice, HASTE MRCP is similar to ERCP but better than CT and B-type ultrasonography, with the merits of fast imaging and high resolution as an ideal sequence for MRCP imaging.
出处 《Journal of Medical Colleges of PLA(China)》 CAS 2003年第3期186-191,共6页 中国人民解放军军医大学学报(英文版)
关键词 magnetic resonance cholangiopancreatography JAUNDICE carcinoma pancreas 胆管疾病 诊断 磁共振胰胆管造影术 内窥镜逆行胰胆管造影术 CT诊断 B超诊断
  • 引文网络
  • 相关文献

参考文献12

  • 1W. Hundt,R. Petsch,J. Scheidler,M. Reiser.[J].European Radiology.2002(7)
  • 2T. K. Kim,J. K. Han,S. J. Kim,S. H. Bae,B. I. Choi.MR cholangiopancreatography: comparison between half-Fourier acquisition single-shot turbo spin-echo and two-dimensional turbo spin-echo pulse sequences[J].Abdominal Imaging.1998(4)
  • 3Fulcher AS,Tumer MA,Capps GW et al.Half-Fourier RARE MR cholangiopancreatography: Experience in 300 subjects[].Radiology.1998
  • 4Wielopolski PA,Gaa J,Wielopolski DR et al.Breath-hold MR cholangiopancreatography with three-dimensional, segmented, echo-planar imaging and volume rendering[].Radiology.1999
  • 5Yamashita Y,Tang Y,Namimoto T et al.MR imaging of the liver: Comparison between single-shot turbo echo-planar and half-Fourier rapid acquisition with relaxation enchancement sequences[].Radiology.1998
  • 6Regan F,Smith D,Khazan R et al.MR cholangiography in biliary obstruction using half-Fourier acquisition[].Journal of Computer Assisted Tomography.1996
  • 7Tang Y,Yamashita Y,Namimoto T et al.-weighted MR imaging: Comparison of conventional half-Fourier single-shot turbo spinecho, breath-hold turbo spin-echo, and respiratory-triggered turbo spin-echo sequences[].Radiology.1997
  • 8Adamek HE,Acbert J,Breer H et al.Pancreatic cancer detection with magnetic resonance cholargiopancreatography and endoscopic retrograde cholangiopancreatography a prospective controlled study[].The Lancet.2000
  • 9Regan F.Clinical applications of half-Fourier (HASTE) MR sequences in abdominal imaging[].Magnetic Resonance Imaging.1999
  • 10Irie H,Honda H,Tajima T et al.Optimal MR cholangio-pancreato-graphic sequence and its clinical application[].Radiology.1998