期刊文献+

High-temperature wear resistance,oxidation resistance and melting loss resistance of plasma cladded Co06–Ni60A composite coating for coppery blast furnace tuyere

原文传递
导出
摘要 To improve the high-temperature service properties of coppery tuyere,Co06 coating with a Ni60A interlayer was prepared on copper by plasma cladding.Ni60A interlayer acted as a bridge to promote the element diffusion,thus achieving metallurgical bonding.Due to the strengthening effect ofγ-Co,Cr_(23)C_(6)and Cr_(7)C_(3)phases,the wear resistance of Co06–Ni60A coating was much higher than that of copper substrate.As the temperature increased,the wear resistance of coating decreased first and then increased.The coating exhibited better wear resistance at 600℃ due to the oxidation wear mechanism.Compared with copper substrate and Ni60A,the oxidation resistance of Co06 was increased by 6.0 and 1.9 times,respectively.For melting loss resistance,Co06–Ni60A coating was superior to Ni60A single-layer coating,but the molten iron can still form a micro-metallurgical bonding with the coating surface.
出处 《Journal of Iron and Steel Research International》 2025年第6期1491-1501,共11页 钢铁研究学报(英文版)
基金 supported by the University Synergy Innovation Program of Anhui Province(Grant Nos.GXXT-2023-025 and GXXT-2023-026) Natural Science Foundation of Anhui Province(Grant Nos.2008085ME149,2308085QE132 and 2308065ME171) Anhui University Scientific Research Project(Grant Nos.2022AH040247,2023AH051660,2023AH051670 and 2023AH051671).
作者简介 Chao Zhang,zhangchao@tlu.edu.cn;Yu-wen Zhang,zyw2007@shu.edu.cn;Dong-sheng Wang,wangdongsheng@tlu.edu.cn。