摘要 优化流量仪表配置,合理选用节能型计量仪表,正成为企业节能增效的重要措施之一。针对标准孔板流量计在实际应用中压力损失大的局限性,介绍了平衡流量计的优化测量原理和性能优势,结合A+K平衡流量计在常减压装置蒸汽计量中的实际应用,对比分析了改造前后流量计能耗及运行成本,分析评价了采用A+K平衡流量计后的节能效果,认为在蒸汽流量测量中采用A+K平衡流量计优化流量仪表配置,在提高蒸汽计量精度的同时,可以降低仪表运行成本,减少蒸汽管网损耗,具有很好的节能效果。 Optimizing the configuration of flow meter and reasonably selecting the measurement instruments of energy conservation are becoming one of the important measures for energy conservation and efficiency improvement for enterprises.In view of the limitations of the standard orifice flow meter with high pressure loss in practical application,the optimized measurement principle and performance advantages of the balanced flow meter have been introduced.Combined with the practical application of A+K balanced flow meter in the steam measurement of atmospheric and vacuum devices,the energy consumption and operating cost of the flow meter before and after the transformation are compared and analyzed,and the energy conservation effect of the A+K balanced flow meter is analyzed and evaluated.In steam flow and measurement,using A+K balanced flow meter and optimizing the configuration of flow meter can not only improve the accuracy of steam measurement,but can reduce the operating cost of the instrument,reduce the loss of steam pipeline,and have a good energy conservation effect.
作者 李景平 LI Jingping(Quality Inspection and Measurement Center of Lanzhou Petrochemical Company,CNPC)
出处 《石油石化节能与计量》 CAS 2024年第10期32-35,共4页 Energy Conservation and Measurement in Petroleum & Petrochemical Industry
关键词 平衡流量计 孔板流量计 蒸汽流量 压力损失 动力损耗 balanced flow meter orifice plate flow meter steam flow pressure loss power loss
作者简介 李景平,高级工程师,1996年毕业于抚顺石油学院(热工计量与测试专业),从事企业计量检定、能源计量、节能监测等技术管理工作,13659441892,lijingping@petrochina.com.cn,甘肃省兰州市西固区玉门街10号,730060。
  • 相关文献

参考文献6

二级参考文献18

  • 1Marshall Space Flight Center, Balanced Flow Meters Without Moving Parts. http://www.nasa.gov/centers.
  • 2Staff Writers. NASA Marshall Develops Faster Cheaper Fluid Flow Meter. http://www.nasa.gov/centers.
  • 3Banlanced flow meter by A+Flowtek, PPR-501-1 (内部资料 2006).
  • 4Report of BFM Testing in 2004 Feb 05, NASA/MSFC/ A+FLOWTEK.
  • 5GB/T2624-2006.用安装在圆形截面管道中的差压装置测量满管流体流量.,2006..
  • 6Quality Monitoring and Control. Thermodynamic and Transport analysis of a Bernoulli flow meter system for any real fluid for NASA Marshall space. 2006.
  • 7Anthony R Kelley. NASA Marshall Space Flight Center.(内部资料 2005).
  • 8GB/T 2624-93流量测量节流装置用孔板、喷嘴、文丘里管测量充满圆管的流体流量[S].
  • 9陈家庆,王波,吴波,初庆东.标准孔板流量计内部流场的CFD数值模拟[J].实验流体力学,2008,22(2):51-55. 被引量:36
  • 10于杰.多孔平衡节流装置应用特点及工程考虑[J].医药工程设计,2008,29(5):45-48. 被引量:10