期刊文献+

火灾下双钢管混凝土复合短柱的性能与承载力计算方法 被引量:1

Performance and bearing capacity calculation method of concrete-filled double steel tubular composite stub columns under fire
在线阅读 下载PDF
导出
摘要 为研究双钢管混凝土复合短柱的耐火性能,建立了双钢管混凝土复合短柱精细化数值模型,在类似构件试验成果验证的基础上,开展其高温反应规律和耐火性能影响因素研究;全面分析了内管径厚比、外管径厚比、内外管直径比等参数的影响,以及不同截面组合形式(内圆外圆、内方外圆和内圆外方)双钢管混凝土短柱的耐火极限。基于热传导分析理论推导双钢管混凝土短柱截面的温度场分布公式,并根据有限元模拟结果对公式进行修正;最后基于温度等效原理进一步提出了火灾条件下双钢管混凝土短柱截面温度场的简化计算公式和承载力计算方法。结果表明:双钢管混凝土复合短柱具有较好的耐火性能,在直径不变时增大内钢管的厚度以及在厚度不变时增加内钢管的直径都有利于耐火极限的提高;在荷载作用和含钢率相同的条件下,不同截面组合形式的双钢管混凝土短柱耐火极限相差不大,但总体上双圆钢管混凝土短柱的耐火性能偏优;提出的温度场简化计算公式和基于等效温度的承载力计算方法与有限元结果相对误差都在15%以内。 In order to study the fire resistance of concrete-filled double steel tubular composite stub columns(CFDST),a refined numerical model of CFDST was established.Based on the verification of test results of similar components,the high-temperature response law and fire resistance influence factor of CFDST were analyzed.The effects of internal pipe diameter thickness ratio,external pipe diameter thickness ratio,internal and external pipe diameter ratio were comprehensively analyzed.The fire resistance limits of CFDST with different section combinations(inner circle and outer circle,inner square and outer circle,inner circle and outer square)were compared and analyzed.Based on the theory of heat conduction analysis,the temperature field distribution formula of CFDST section was deduced,and the formula was modified according to the results of finite element simulation.Finally,based on the principle of temperature equivalence,the simplified calculation formula and bearing capacity calculation method of section temperature field of CFDST under fire were further proposed.The results show that CFDST has good fire resistance.Increasing the thickness of the inner steel tube when the diameter is unchanged and increasing the diameter of the inner steel tube when the thickness is unchanged are conducive to the improvement of the fire resistance limit.Under the condition of the same load and steel content,the fire resistance limit of CFDST with different section combinations is almost the same,but on the whole,the fire resistance of double circular steel tube concrete stub column is better.The difference between the simplified calculation formula of temperature field,the bearing capacity calculation method and the finite element results is less than 15%.
作者 杨青天 多飞 张晋川 侯立群 陈适才 YANG Qingtian;DUO Fei;ZHANG Jinchuan;HOU Liqun;CHEN Shicai(Department of Civil Engineering,Beijing University of Technology,Beijing 100124,China;China Railway Construction Group Co.,Ltd.,Beijing 100040,China)
出处 《建筑科学与工程学报》 北大核心 2024年第1期128-137,共10页 Journal of Architecture and Civil Engineering
基金 国家自然科学基金项目(51678016,52278471)。
关键词 双钢管混凝土复合短柱 温度场 耐火极限 简化计算公式 承载力 concrete-filled double steel tubular composite stub column temperature field fire resistance limit simplified calculation formula bearing capacity
作者简介 通信作者:陈适才(1979-),男,工学博士,教授,博士生导师,E-mail:shicaichen@163.com。
  • 相关文献

参考文献1

二级参考文献20

  • 1张素梅,郭兰慧,叶再利,王玉银.方钢管高强混凝土轴压短柱的试验研究[J].哈尔滨工业大学学报,2004,36(12):1610-1614. 被引量:28
  • 2蔡绍怀 焦占栓.钢管混凝土短柱的基本性能和强度计算[J].建筑结构学报,1984,(6):13-34.
  • 3钟善桐 王用纯.钢管混凝土轴心受压构件计算理论的研究[J].建筑结构学报,1980,(1):61-71.
  • 4林立岩,等.以钢管混凝土为核心的高强混凝土叠合柱[C]∥第三届中日建筑结构技术交流会论文集,深圳,1997.
  • 5CECS159:2004矩形钢管混凝土结构技术规程[S].北京:中国计划出版社,2004.
  • 6DBJ13-51-2010钢管混凝土结构技术规程[S].
  • 7CECS188:2005钢管混凝土叠合柱结构技术规程[S].北京:中国计划出版社,2005.
  • 8JGJ3-2011高层建筑混凝土结构技术规程[S].北京:中国建筑工业出版社,2011.
  • 9CECS28:1990钢管混凝土结构设计与施工规程[S].北京:中国计划出版社,1990.
  • 10GB50010--2010混凝土结构设计规范[S].北京:中国建筑工业出版社,2010.