摘要
国标法测定工作场所空气中苯胺时苯存在胺峰的对称性不佳和标准曲线线性相关性较差的问题,对国标法溶剂解吸气相色谱法测定苯胺进行了改进。主要改进措施有:硅胶管采集样品,采用CP-Sil 8 CB for Amines胺类专用色谱柱分离,确定最优色谱条件和最佳解吸液。该方法检出限、定量下限、最低检出浓度、最低定量浓度、精密度、平均解析效率等各项指标均符合检测要求,适合工作场所空气中苯胺的检测。
In the determination of aniline in the air of workplaces using the national standard method,there are issues with poor symmetry of amine peaks and poor linear correlation of standard curves in benzene.Therefore,the national standard solvent desorption gas chromatography method for the determination of aniline has been improved.The main improvement measures include:collecting samples using a silicone tube,using a CP-Sil 8 CB for Amines amine specific chromatographic column for separation,and determining the optimal chromatographic conditions and desorption solution.The detection limit,lower limit of quantification,minimum detection concentration,minimum quantification concentration,precision,average resolution efficiency and other indicators of this method meet the detection requirements and are suitable for the detection of aniline in the air of workplaces.
作者
曹殿荣
Cao Dianrong(Jiangsu Ousa Environmental Testing Technology Co.,Ltd.,Nanjing Jiangsu 210032,China)
出处
《山西化工》
CAS
2023年第11期51-52,共2页
Shanxi Chemical Industry
关键词
苯胺
溶剂解吸气相色谱法
工作场所
aniline
solvent desorption gas chromatography
workplace
作者简介
曹殿荣,女,1989年出生,毕业于黄山学院,本科,中级工程师,研究方向为职业卫生检测与评价、放射卫生检测与评价、安全评价等。