摘要
简要介绍了空分设备系统流程,结合空分设备分子筛纯化器进水故障的实际案例,分析分子筛纯化器进水的原因、现象和处理措施,阐述了为避免分子筛纯化器进水故障的发生,提出了技改和预防措施。
This article briefly introduces the system process of the air separation equipment,analyzes the causes,phenomena,and treatment measures of water ingress in the molecular sieve purifier based on the actual case of water ingress failure in the molecular sieve purifier of the air separation equipment,and elaborates on the technical improvement and preventive measures to avoid the occurrence of water ingress failure in the molecular sieve purifier.
作者
孙素霞
王志勇
屈联西
SUN Su-xia;WANG Zhi-yong;QU Lian-xi(Henan Yuguang Gold Lead Co.,Ltd.Oxygen Plant,Jiyuan,Henan 454650)
出处
《世界有色金属》
2023年第12期163-165,共3页
World Nonferrous Metals
关键词
空分设备
空气冷却塔
分子筛纯化器
进水故障
处理措施
技改措施
air separation equipment
Air cooling tower
Molecular sieve purifier
Water ingress fault
Handling measures
Technical transformation measures
作者简介
孙素霞,女,1975年生,助理工程师,高级深冷气体分离工,研究方向:冶金工程。