摘要
广东省惠州市某城镇污水处理厂设计处理能力为2 000 m3/d,负荷率偏低,运维水平不高。本文以该城镇污水处理厂为例,进行处理现状评估及运行效能分析,并结合存在的问题,提出相应建议,旨在为其他城镇污水处理厂提供运维经验。
The designed treatment capacity of an urban sewage treatment plant of Huizhou City,Guangdong Province is 2 000 m3/d,with a low load rate and low operation and maintenance level.Taking the urban sewage treatment plant as an example,this paper evaluates the treatment status and analyzes its operational efficiency,and proposes corresponding suggestions based on existing problems,aiming to provide operation and maintenance experience for other urban sewage treatment plants.
作者
陈羿材
CHEN Yicai(Guangdong Provincial Academy of Environmental Science;Guangdong Huankeyuan Environmental Technology Co.,Ltd.,Guangzhou 510045,China)
出处
《中国资源综合利用》
2023年第9期190-192,共3页
China Resources Comprehensive Utilization
关键词
城镇污水处理厂
现状评估
运行效能
负荷率
urban sewage treatment plant
status evaluation
operational efficiency
load rate
作者简介
陈羿材(1993-),男,陕西西安人,硕士,助理工程师。研究方向:生态环境规划与咨询、农村生活污水治理、农业面源污染防治。