电感耦合等离子体发射光谱法测定可溶性镁合金中高含量镍 被引量:3

Determination of high content nickel in soluble magnesium alloys by inductively coupled plasma atomic emission spectrometry
在线阅读 下载PDF
导出
摘要 建立电感耦合等离子体发射光谱法测定可溶性镁合金中高含量镍元素含量的分析方法。采用10 mL盐酸溶液(1+1)溶解可溶性镁合金样品,选择Ni 216.556 nm为分析谱线,采用基体匹配法建立校正曲线,通过基体匹配消除基体干扰,使用电感耦合等离子体发射光谱仪测定样品溶液中镍含量。镍元素质量分数在0.5%~5%范围内与发射光谱强度线性关系良好,相关系数为0.9999。样品加标平均回收率为99.0%~101.7%,测定结果的相对标准偏差为0.70%~1.15%(n=6)。该方法可用于可溶性镁合金中高含量镍元素的测定。 An analytical method for the determination of nickel with high content in soluble magnesium alloys by inductively coupled plasma atomic emission spectrometry was established.The soluble magnesium alloy sample was dissolved with 10 mL hydrochloric acid solution(1+1),Ni 216.556 nm was selected as the analytical spectral line,the calibration curve was established by matrix matching method,matrix interference was eliminated by matrix matching,the content of nickel in the sample solution was determined by inductively coupled plasma atomic emission spectrometer.The linear relationship between the emission spectrum intensity and the mass fraction of nickel was good in the range of 0.5%-5%,the correlation coefficient was 0.9999.The average recovery rate of spiking was 99.0%-101.7%,and the relative standard deviation of the determination results was 0.70%-1.15%(n=6).The method can be used for the determination of high content nickel in soluble magnesium alloys.
作者 张喜林 钱亚锋 孙志阳 吴洋 ZHANG Xilin;QIAN Yafeng;SUN Zhiyang;WU Yang(Hebi Product Quality Inspection and Testing Center,Hebi 458030,China)
出处 《化学分析计量》 CAS 2023年第7期17-20,共4页 Chemical Analysis And Meterage
基金 国家标准修订项目(国标委发[2022]22号20220714-T-610) 河南省市场监督管理局科技计划项目(2020sj44)。
关键词 电感耦合等离子体发射光谱法 可溶性镁合金 inductively coupled plasma emission spectrometry soluble magnesium alloy nickel
作者简介 通信作者:张喜林,本科,工程师,主要从事新型镁合金元素检测研究。
  • 相关文献

参考文献13

二级参考文献158

共引文献146

同被引文献36

引证文献3

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部