摘要
基于国家大力推进新农村建设的需要和顺应国家着力发展装配式建筑的趋势,提出了一种新型双层波形板-混凝土组合墙,考虑波形钢板不同组合类型,采用ABAQUS对该新型组合墙的抗震性能进行研究分析。结果表明空腔暗柱是影响组合墙抗震性能的重要因素。空腔暗柱大,组合墙的水平承载力和抗侧刚度提高,而耗能能力减弱。
Based on the needs of the country to vigorously promote the construction of new rural areas and the trend of the country to develop prefabricated buildings,a new type of double-layer corrugated plate-concrete composite wall is proposed.Considering different combinations of corrugated steel plates,the seismic performance of the new composite wall was analyzed by ABAQUS.The results show that the cavity hidden column is an important factor affecting the seismic performance of the composite wall.If the cavity column is large,the horizontal bearing capacity and lateral stiffness of the composite wall are improved,but the energy dissipation capacity is weakened.
作者
吴涛
杨旭
彭剑锋
高怡
胡钢
Wu Tao;Yang Xu;Peng Jianfeng;Gao Yi;Hu Gang(School of Civil Engineering,Suzhou University of Science and Technology,Suzhou 215011,China)
出处
《山西建筑》
2023年第6期62-65,共4页
Shanxi Architecture
关键词
双层-波形板混凝土组合墙
空腔暗柱
抗震性能
d ouble-layer-corrugated slab concrete composite wall
cavity hidden column
seismic performance
作者简介
吴涛(1996-),男,在读硕士,从事混凝土结构与组合结构理论及其应用研究。