期刊文献+

液相色谱-串联质谱法测定畜禽肉和鸡蛋中氨基酸含量 被引量:5

Determination of amino acids in meat and eggs by liquid chromatography-tandem mass spectrometry
在线阅读 下载PDF
导出
摘要 建立了微波水解技术和液相色谱-串联质谱技术测定畜禽肉和鸡蛋中17种氨基酸含量的方法。以传统酸水解技术为对照,比较分析微波水解和高压水解技术的不同。以0.1%(体积分数)甲酸水溶液+10 mmol/L乙酸铵溶液和甲醇为流动相,梯度洗脱,串联质谱正离子模式进行监测,外标法定量。结果表明,与传统的氨基酸分析仪相比,微波水解-液相色谱-串联质谱技术法无需进行样品的衍生可直接测定,缩短了样品的检测时间。该检测方法的线性范围为5~375μg/L,相关系数R^(2)≥0.993,检出限为0.025~0.250μg/kg,加标回收率为85%~96%,精密度为0.01%~0.71%。该方法缩短了蛋白质的水解时间,快速简便、灵敏度较高、数据准确可靠,可用于畜禽肉和鸡蛋中17种氨基酸的测定。 A method for the determination of 17 amino acids in meat and eggs was established by microwave hydrolysis and liquid chromatography-tandem mass spectrometry(LC-MS/MS).Compared with the traditional acid hydrolysis technology,the differences between microwave hydrolysis and high-pressure hydrolysis technology were compared and analyzed.Based on the comparative analysis of traditional acid hydrolysis,microwave hydrolysis,and high-pressure hydrolysis methods,gradient elution was carried out with 0.1%formic acid aqueous solution+10 mmol/L ammonium acetate solution and methanol as mobile phases.Tandem mass spectrometry was used for monitoring and analysis in positive ion mode and external standard method was used for quantification.Results showed that compared with the traditional amino acid analyzer,the microwave hydrolysis-LC-MS/MS method could be used for direct determination of samples without derivatization,which shortened the detection time of samples.The linear range of this method was 5-375μg/L,the correlation coefficients were more than 0.993,the detection limit was 0.025-0.250μg/kg,the recovery rate of standard addition was 85%-96%,and the relative standard deviations were 0.01%-0.71%.The method shortens the protein hydrolysis time,has high sensitivity,accurate,and reliable data,and can be used for the determination of 17 amino acids in meat and eggs.
作者 李智 周灿 费华熙 王素利 郑连姬 LI Zhi;ZHOU Can;FEI Huaxi;WANG Suli;ZHENG Lianji(Chongqing Food Industry Research Institute Co.Ltd.,Chongqing 400042,China;China National Light Industry Council Inspection Station for Food Quality Chongqing Branch,Chongqing 400042,China)
出处 《食品与发酵工业》 CAS CSCD 北大核心 2023年第3期314-321,共8页 Food and Fermentation Industries
基金 重庆市科研机构绩效激励引导专项项目(cstc2019jxjl120001) 重庆市渝中区基础研究与前沿探索项目(20180145)。
关键词 微波水解 液相色谱-串联质谱法 氨基酸 microwave hydrolysis liquid chromatography-tandem mass spectrometry amino acids
作者简介 第一作者:李智,硕士,高级工程师;通信作者:郑连姬,正高级工程师,E-mail:26819079@qq.com。
  • 相关文献

参考文献8

二级参考文献143

  • 1朱曙东,赵皓.氨基酸的高效液相色谱分析[J].色谱,1994,12(1):20-24. 被引量:57
  • 2傅亮,倪冬姣,张水华.氨基酸高效液相色谱分析[J].仲恺农业技术学院学报,1994,7(2):76-82. 被引量:9
  • 3林文津,徐榕青,张亚敏.正交实验优化中药太子参氨基酸超声提取工艺[J].海峡药学,2006,18(1):33-35. 被引量:8
  • 4.GB/T 14965—94.食品中氨基酸的测定方法(中国国标)[S].中华人民共和国卫生部,1994—09-01实施..
  • 5中华人民共和国卫生部药典委员会.中华人民共和国卫生部药典[M].北京:人民卫生出版社,1990.89.
  • 6Joergensen L,Thestrup H N.J Chromatogr A,1995,706:421
  • 7Weiss M,Manneberg M,Juranville J-F,Lahm H W,Fountoulakis M.J Chromatogr A,1998,795:263
  • 8Ekman P,Jager O.Anal Biochem,1993,214:138
  • 9D'Aniello A,Petrucelli L,Gardner C.Anal Biochem,1993,213:290
  • 10Thoma R S,Crimmins D L.J Chromatogr,1991,537:153