摘要
采用数理统计分析方法,对比分析了现场钢样板重防腐涂层附着力和涂层厚度、钢管桩喷涂现场各涂层厚度的标准差和变异系数。结果表明,涂层厚度越大,其标准差和变异系数越大;喷涂面积越大,涂层厚度标准差和变异系数越大。通过设置石墨烯光敏复合增强纤维预浸带作为钢管桩重防腐涂层的中间漆增强层,使钢管桩中间漆与面漆的附着力提高24%,并提高海上风电钢管桩飞溅区重防腐涂层的综合防腐性能,同时其标准差和变异系数与现场钢样板相同。
In this paper,mathematical statistical analysis was used to compare and analyze the standard deviation and coefficient of variation of adhesion and coating thickness of heavy-duty anti-corrosion coating of steel sample and the thickness of each coating of the spraying of steel pipe piles on site.The results showed that a thicker coating thickness led to an increase in standard deviation and coefficient of variation.And as the sprayed area increased,the standard deviation and coefficient of variation of the coating thickness increased accordingly.The graphene photosensitive composite reinforced fiber prepreg tape was set as the intermediate paint reinforcement layer of the heavy-duty anti-corrosion coating to improve the adhesion to the topcoat by 24%,and improve the comprehensive anti-corrosion ability of the heavy-duty anti-corrosion coating in the splash zone of offshore wind power steel pipe piles.Meanwhile,the standard deviation and coefficient of variation were the same as those of the steel sample.
作者
骆光杰
周茂强
李野
顾勇
LUO Guangjie;ZHOU Maoqiang;LI Ye;GU Yong(Powder China Huadong Engineering Corporation,Hangzhou 311122,China;Zhejiang Huadong Engineering Consulting Co.Ltd.,Hangzhou 311122,China;Shanghai SINO-DRAGON Intelligent Techology Co.Ltd.,Shanghai 200240,China)
出处
《新型建筑材料》
2023年第1期74-78,共5页
New Building Materials
基金
国家自然科学基金项目(52179122)。
关键词
海浪飞溅区
纤维增强高性能树脂
防腐复合涂层
质量评价
splash-zone
fiber reinforced high performance resin
anti-corrosion composite coating
quality evaluation
作者简介
骆光杰,男,1979年生,正高级工程师,主要从事电力项目管理研究,E-mail:lou_gj@hdec.com;通讯作者:李野,工程师,E-mail:yepply@126.com。