摘要 为了实时监测和评价火电机组一次调频性能,开发了火电机组一次调频性能实测监测系统。该系统具有一次调频参数异动感知、一次调频性能量化预测及自适应校正等关键功能。某机组的实际应用表明,该系统能够实现火电机组一次调频关键参数的实时监测和调频性能的准确预测。 In order to monitor and evaluate the primary frequency modulation performance of thermal power unit in real time,a performance monitoring system for primary frequency modulation of thermal power unit was developed.This system has the key functions such as abnormal response of parameter variation,performance quantitative prediction of primary frequency modulation and self-adaptive correction,etc.The practical application of a unit shows that the system can realize the real-time monitoring for key parameter variation of primary frequency modulation of thermal power unit and predict the frequency modulation performance accurately.
作者 盛锴 邹鑫 朱晓星 陈珣 SHENG Kai;ZOU Xin;ZHU Xiao-xing;CHEN Xun(State Grid Hunan Electric Power Company Research Institute,Changsha,China,410007;State Grid Hunan Electrie Power Co.,Ltd.,Chungshua,China,410004;Hunan Provincial Key Laboratory of High fficeney&Clean Thermal Power Technologo,Chungha,China,410007;Hunan Xiangdian Test&Research Institute Co.,Ltd.,Chuangshu,China,10006)
出处 《热能动力工程》 CAS CSCD 北大核心 2022年第8期197-203,共7页 Journal of Engineering for Thermal Energy and Power
基金 国网湖南省电力有限公司科技项目(5216A520000D)。
关键词 火电机组 一次调频 实时监测 参数异动感知 性能量化预测 自适应校正 thermal power unit primary frequency control online monitoring parameter variation sensing performance quantitative prediction self-adaptive correction
作者简介 盛锴(1983-),男,湖南长沙人,国网湖南省电力有限公司电力科学研究院高级工程师。
  • 相关文献

参考文献7

二级参考文献69

共引文献187

同被引文献99

引证文献7

二级引证文献21

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部