期刊文献+

耳科影像学的关键技术创新和应用——2020年度国家科学技术进步奖二等奖 被引量:2

The innovation and application of key technologies in the otological radiology——The Second Prize of 2020 National Science and Technology Progress
在线阅读 下载PDF
导出
摘要 耳科疾病病变具有解剖位置深、隐匿微小的特征,传统耳科影像学在临床应用时存在看不清、看不准、看不懂的问题,导致病变影像诊断效能低下。王振常教授团队从创建耳科影像的规范检查方案和系统评价模式、提升耳科疾病的病理生理结构显示能力入手,阐明了搏动性耳鸣全链条发生机制,构建耳科影像检查及诊断新体系,并研制十微米级临床耳科电子计算机断层扫描(computed tomography,CT)专用设备,实现低辐射高质量的成像和病变的精准检查,显著提升了诊断效能。 The otologic diseases features in deep and occult anatomy.The problems of traditional oto-radiology with invisibility,imprecision,and incomprehensibility leads to diagnostic inefficacy.Professor Wang Zhenchang's team developed a canonical oto-radiological examination protocol and systemic evaluation model to improve the visibility of pathophysiological features of otology disease.They illuminated the whole chain mechanism of pulsatile tinnitus,established the radiological examination and evaluation system of oto-radiology,invented micron-level computed tomography specific to clinical otology.By applying this program,they could precisely detect the disease with low-dose as well as high-quality radiological examination.The diagnostic efficacy was improved significantly.
作者 吕晗 赵鹏飞 尹红霞 王振常 Lyu Han;Zhao Pengfei;Yin Hongxia;Wang Zhenchang(Department of Radiology, Beijing Friendship Hospital, Capital Medical University, Beijing 100050, China)
出处 《首都医科大学学报》 CAS 北大核心 2022年第1期13-16,共4页 Journal of Capital Medical University
关键词 搏动性耳鸣 耳聋 眩晕 体层摄影术 X线计算机 诊断 pulsatile tinnitus deafness vertigo tomography X-ray computed diagnosis
作者简介 Corresponding author:王振常,E-mail:cjr.wzhch@vip.163.com。
  • 相关文献

参考文献5

二级参考文献35

  • 1Liu Y,Liu H,Wang Y,et al.Half-scan cone-beam CT fluoroscopy with multiple sources.Med.Phys.,2001,28(7):1466-1471.
  • 2Flohr T G,McCoUough C H,Binder H,et al.First performance evaluation of a dual-source CT (DSCT) system.Eur Radiol.,2006,16:256-268.
  • 3Kachelriess M,Kalender W A.Electrocardiogram-correlated image reconstruction from subsecond spiral computed tomography scans of the heart.Med.Phys.,1998,25(12):2417-2431.
  • 4Flohr T,Ohnesorge B.Heart rate adaptative optimization of spatial and temporal resolution for electrocardiogramgated multislice spiral CT of the heart.J.Comput.Assist.Tomogr.,2001,25(6):907-923.
  • 5Lu W G,Maekie T R.Tomographic motion detection and correction directly in sinogram space.Phys.Med.Biol.,2002,47(8):1267-1284.
  • 6Wang G,Vannier M W.Preliminary study on helical CT algorithms for patient motion estimation and compensation.IEEE Trans.Med.Imag.,1995,14(2):205-211.
  • 7Crawford C R.Respiratory compensation in projection imaging using a magnification and displacement model.IEEE Trans.Med.Imag.,1996,15(3):327-332.
  • 8GrangeatP,Koenig A,Rodet T,et al.Theoretical framework for a dynamic cone-beam reconstruction algorithm based on a dynamic particle model.Phys.Med.Biol.,2002,47(15):2611-2625.
  • 9Linney N C,GTegson P H.Organ motion detection in CT images using opposite rays in fan-beam projection systems.IEEE Trans.Med.Imag.,2001,20(11):1109-1122.
  • 10Yu H Y,Wei Y C,Hsieh J,ct al.Data consistency based translational motion artifact reduction in fan-beam CT.IEEE Trans.Med.Imag.,2006,25(6):792-803.

共引文献108

同被引文献57

引证文献2

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部