期刊文献+

循环流化床锅炉炉内超低排放改造优化调整试验 被引量:1

Optimization and Adjustment Test of Ultra-low Emission in Circulating Fluidized Bed Boiler
在线阅读 下载PDF
导出
摘要 针对燃煤发电厂降低大气污染物排放以满足环保要求,以某发电厂5号锅炉改造为例,介绍了实现循环流化床锅炉炉内脱硝、脱硫的原理,并依据该原理对炉内脱硝、脱硫系统提出了改造和优化调整试验方案。调整后的系统,实现了降低锅炉的NO_(x)和SO_(2)的原始排放、提高炉内脱硫和炉内脱硝效率的目的。 Aiming at reducing the emission of air pollutants in coal-fired power plants to meet the requirements of environmental protection,taking No.5 boiler of a power plant in Hulun Buir as an example,the principle of realizing desulfurization and denitration in circulating fluidized bed boiler is introduced.According to this principle,the experimental scheme of transformation and optimization adjustment of desulfurization and denitration system in furnace is put forward.The adjusted system reduces the original emission of NO_(x) and SO_(2) from the boiler and improves the desulfurization and denitration efficiency in the boiler.
作者 孙晓雷 高云峰 李德永 赵喜斌 SUN Xiaolei;GAO Yunfeng;LI Deyong;ZHAO Xibin(East Hailar Power Plant,Hulun Buir 021000,China;Huaneng East Inner Mongolia Energy Company Limited,Hulun Buir 021008,China)
出处 《吉林电力》 2021年第5期43-45,共3页 Jilin Electric Power
关键词 循环流化床锅炉 脱硫 脱硝 系统改造 优化调整 circulating fluidized bed boiler desulfurization denitration system transformation optimization and adjustment
作者简介 孙晓雷(1987),男,工程师,从事电厂锅炉设备管理及维护工作。