摘要
针对燃煤发电厂降低大气污染物排放以满足环保要求,以某发电厂5号锅炉改造为例,介绍了实现循环流化床锅炉炉内脱硝、脱硫的原理,并依据该原理对炉内脱硝、脱硫系统提出了改造和优化调整试验方案。调整后的系统,实现了降低锅炉的NO_(x)和SO_(2)的原始排放、提高炉内脱硫和炉内脱硝效率的目的。
Aiming at reducing the emission of air pollutants in coal-fired power plants to meet the requirements of environmental protection,taking No.5 boiler of a power plant in Hulun Buir as an example,the principle of realizing desulfurization and denitration in circulating fluidized bed boiler is introduced.According to this principle,the experimental scheme of transformation and optimization adjustment of desulfurization and denitration system in furnace is put forward.The adjusted system reduces the original emission of NO_(x) and SO_(2) from the boiler and improves the desulfurization and denitration efficiency in the boiler.
作者
孙晓雷
高云峰
李德永
赵喜斌
SUN Xiaolei;GAO Yunfeng;LI Deyong;ZHAO Xibin(East Hailar Power Plant,Hulun Buir 021000,China;Huaneng East Inner Mongolia Energy Company Limited,Hulun Buir 021008,China)
出处
《吉林电力》
2021年第5期43-45,共3页
Jilin Electric Power
关键词
循环流化床锅炉
脱硫
脱硝
系统改造
优化调整
circulating fluidized bed boiler
desulfurization
denitration
system transformation
optimization and adjustment
作者简介
孙晓雷(1987),男,工程师,从事电厂锅炉设备管理及维护工作。