摘要
制作了一个三电极电致膜抑制器,考察了加电方式、串连电阻阻值、电极间距对改善噪声的影响。相较于传统两电极抑制器,优化得到的三电极抑制器在抑制CO32--淋洗液时在噪声(~2.5倍)和信噪比(2.5~3.6倍)方面皆有一定程度的改善;所得三电极抑制器稳定性好,可与离子色谱结合后检测饮料中6种常见阴离子含量。
A three-electrode electrodialytic membrane anion suppressor( t EMS) was fabricated,the effects of charging way,resistance value of serial resistance and the gap of two cathodes on noise reduction were studied.Compared with the conventional two-electrode counterpart,tEMS showed ~2. 5 fold lower noise level,as well as 2. 5-3. 6 fold higher signal and noise ratio towards common inorganic anions. The obtained t EMS has good stability and could be used to determine six inorganic anions in several types of drinks.
作者
黄颖芬
孙玥
杨丙成
章飞芳
HUANG Yingfen;SUN Yue;YANG Bingcheng;ZHANG Feifang(Pharmaceutical Engineering and Process of Chemical Engineering Research Center of Ministry of Education,School of Pharmacy,East China University of Science and Technology,Shanghai 200237)
出处
《分析试验室》
CAS
CSCD
北大核心
2021年第7期818-822,共5页
Chinese Journal of Analysis Laboratory
基金
国家自然科学基金项目(21874044,21974044)资助。
关键词
离子色谱
电致膜抑制器
碳酸根淋洗液
三电极
噪声
ion chromatography
electrodialytic membrane suppressor
carbonate eluent
three-electrode
noise
作者简介
黄颖芬,女(1996-),硕士研究生。研究方向:离子色谱相关技术及应用,sarah_liyf@foxmail.com;通信作者:章飞芳,女(1975-),博士,副研究员。研究方向:药物分析相关研究,zhangff@ecust.edu.cn。