摘要
钢中的夹杂物对钢材的性能有重要影响,为了监控夹杂物冶炼水平,需要对钢中夹杂物含量进行定量分析,通过扫描电镜利用背散射电子成像和X射线能谱分析钢中夹杂物,从样品制备以及分析时的放大倍数、帧数、图像像素、采集计数、束斑、采集驻留时间、灰度值、阈值对分析结果的影响进行了详细的分析,旨在优化各种设备参数,提高分析准确度。
Inclusions in steel have an important influence on the properties of steel,in order to monitor the smelt⁃ing level of inclusions,the inclusion content of steel Quantitative analysis,analysis of inclusions in steel by scanning electron microscopy with back-scatter electron imaging and x-ray energy spectrum,the effects of magnification,frame number,image Pixel,sampling count,beam spot,sampling dwell time,gray value and threshold on the analy⁃sis results were analyzed in details,in order to optimize the parameters of various equipment,improve the accuracy of analysis.
作者
宫巨龙
张春花
Gong Julong;Zhang Chunhua(HBISTangshang Stainless Steel Co.,Ltd,Tangshan 063100,China)
出处
《特钢技术》
CAS
2020年第4期49-52,共4页
Special Steel Technology
关键词
背散射电子
能谱分析
成分构成
分析参数
非金属夹杂物
back-scattered electron
energy spectrum analysis
composition
analysis parameter
nonmetallic inclusion
作者简介
宫巨龙(1983一),男,大学本科,工程师,毕业于河北理工大学测控技术与仪器专业。现供职于河钢集团唐山不锈钢有限责任公司设备科,从事设备管理与点检维护工作。