期刊文献+

真空采血管类型对生化检验结果的影响 被引量:1

Influence Analysis of the Types of Vacuum Blood Collection Tubes on the Results of Biochemical Tests
在线阅读 下载PDF
导出
摘要 目的探讨不同类型的真空采血管对生化检验结果的影响。方法选取2018年3月至2019年5月本院收治的110例患者作为研究对象,取清晨空腹静脉血,依次放置在普通采血管(设为A组)、肝素锂抗凝真空采血管(设为B组)、分离胶真空采血管(设为C组)、EDTA-K2抗凝真空采血管(设为D组)及枸橼酸钠真空采血管(设为E组),将血清或血浆分离后通过全自动生化分析仪及配套的设备检测18项生化检验指标。比较各组生化检验结果。结果E组生化检验指标(GGT、GLU、CK-MB、CK)与A组、B组、C组及D组对比,差异有统计学意义(P<0.05);除Cr外,D组、E组各项生化检验项目的检验结果与A组、B组、C组对比,差异有统计学意义(P<0.05)。结论在生化检验中,采用不同的真空采血管会给部分检验指标带来一定的影响,建议尽可能选择对检验结果影响较小的真空采血管,以保证临床检验结果的准确性。 Objective Explore the influence of different types of vacuum blood collection vessels on biochemical test results.Method A total of 110 patients admitted to our hospital from March 2018 to May 2019 were selected as the research objects.Morning fasting venous blood was collected and placed in common blood collection vessel(group A),heparin lithium anticoagulant vacuum blood collection vessel(group B),separation gel vacuum blood collection vessel(group C),EDTA-K2 anticoagulant vacuum blood collection vessel(group D)and sodium citrate vacuum blood collection vessel(group E),after the separation of serum or plasma,18 biochemical indexes were detected by automatic biochemical analyzer and supporting equipment.The biochemical test results of each group were compared.Result The biochemical indexes(GGT,Glu,CK-MB,CK)of group group E were significantly different from those of group A,group B,group C and group D(P<0.05);Except for Cr,the biochemical test results of group D and group E were significantly different from those of group A,group B and group C(P<0.05).Conclusion In the biochemical test,the use of different vacuum collection vessels will bring some influence on some test indexes.It is suggested that the vacuum collection vessels with less influence on the test results should be selected as far as possible to ensure the accuracy of clinical test results.
作者 孟宪良 MENG Xianliang(Donggang Central Hospital,Dandong 118300,China)
机构地区 东港市中心医院
出处 《中国医药指南》 2020年第36期95-96,共2页 Guide of China Medicine
关键词 生化检验 真空采血管 检验结果 准确性 Biochemical test Vacuum blood collection tube Test results Accuracy
  • 相关文献

参考文献9

二级参考文献47

共引文献40

同被引文献8

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部