摘要
研究了采用钠皂化P507(2-乙基己基膦酸单-2-乙基己基脂)从电解精炼制备超高纯钴的高浓度氯化钴电解质水溶液中萃取分离钴、镍,考察了振荡时间、静置分相时间、温度、相比(Vo/Va)、P507体积分数及有机相皂化率对萃取的影响。结果表明:在振荡时间15 min、静置分相时间10 min、温度20℃、初始水相pH=3.50、相比Vo/Va=1/1、P507体积分数20%及有机相皂化率65%条件下,钴、镍分离比为2940/1,二者得到有效分离。
Solvent extraction of cobalt and nickel from high concentration cobalt chloride solution used to prepare ultrahigh purity cobalt by electro-refining using sodium-saponified P507(2-ethylhexylphosphoric acid mono-2-ethylhexyl ester)was studied.The effects of oscillation time,phase disengagement time,temperature,ratio of organic phase-to-aqueous phase(Vo/Va),P507 volume fraction and saponification rate of organic phase on extraction of cobalt and nickel were examined.The results show that under the optimum conditions of extraction oscillation time of 15 min,phase disengagement time of 10 min,temperature of 20℃,initial aqueous phase pH of 3.50,Vo/Va of 1/1,P507 volume fraction of 20%and organic phase saponification of 65%,the separation ratio of cobalt and nickel is 2940/1,good separation effect is obtained.
作者
于凯
艾峥嵘
谢宏伟
刘吉利
宁志强
YU Kai;AI Zhengrong;XIE Hongwei;LIU Jili;NING Zhiqiang(School of Metallurgy,Northeastern University,Shenyang 110819,China;School of Materials Science and Engineering,Northeastern University,Shenyang 110819,China;Key Laboratory for Anisotropy and Texture of Materials Ministry of Education,Northeastern University,Shenyang 110819,China)
出处
《湿法冶金》
CAS
北大核心
2020年第6期502-506,共5页
Hydrometallurgy of China
基金
国家重点研发计划资助项目(2017YFB0305401)。
关键词
氯化钴溶液
溶剂萃取
P507
钴
镍
分离
cobalt chloride solution
solvent extraction
P507
cobalt
nickel
separation
作者简介
第一作者:于凯(1983—),男,硕士,实验师,主要研究方向为高纯金属制备;通信作者:谢宏伟(1977—),男,博士,副教授,主要研究方向为熔盐及熔盐电化学法制备材料过程物理化学,E-mail:xiehw@smm.neu.edu.cn。