期刊文献+

电感耦合等离子体原子发射光谱(ICP-AES)法测定高铋铅中的杂质元素 被引量:7

Determination of Impurity Elements in High Bismuth Lead by Inductively Coupled Plasma Atomic Emission Spectrometry
在线阅读 下载PDF
导出
摘要 采用硝酸+酒石酸溶解试样,电感耦合等离子体原子发射光谱(ICP-AES)法测定高铋铅中的铜、铁、镍、镉、砷、锑和铋的含量。测定范围为ωCu(0.10%~5.00%)、ωFe(0.001%~0.10%)、ωNi(0.001%~0.10%)、ωCd(0.001%~0.050%)、ωAs(0.50%~7.00%)、ωSb(0.50%~5.00%)、ωBi(1.00%~7.00%)。经加标回收实验,各元素的加标回收率为91.5%~115%。方法准确简单,适用于高铋铅中铜、铁、镍、镉、砷、锑和铋量的同时测定。 Using nitric acid and tartaric acid to dissolve the sample,the contents of copper,iron,nickel,cadmium,arsenic,antimony and bismuth in high bismuth lead were determined by inductively coupled plasma atomic emission spectrometry.Determination rangeωCu(0.10%—5.00%),ωFe(0.001%—0.10%),ωNi(0.001%—0.10%),ωCd(0.001%—0.050%),ωAs(0.50%—7.00%),ωSb(0.50%—5.00%),ωBi(1.00%—7.00%).The recovery of each element is 91.5%—115%.The method is accurate and simple.It is suitable for the simultaneous determination of copper,iron,nickel,cadmium,arsenic,antimony and bismuth in high bismuth lead.
作者 韩晓 HAN Xiao(BGRIMM MTC Technology Co.,Ltd.,Beijing 102628,China)
出处 《中国无机分析化学》 CAS 2020年第4期71-75,共5页 Chinese Journal of Inorganic Analytical Chemistry
关键词 高铋铅 电感耦合等离子体原子发射光谱法 杂质元素 high bismuth lead inductively coupled plasma atomic emission spectrometry impurity elements
作者简介 韩晓,女,高级工程师,主要从事地矿和冶金样品的无机元素分析检测研究,E-mail:404864354@qq.com。
  • 相关文献

二级参考文献67

共引文献242

同被引文献40

引证文献7

二级引证文献27

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部