水电厂计算机监控系统上位机UPS电源改造与优化 被引量:6

Improvement and Optimization of UPS Power Supply of Upper Computer Monitoring System in Hydropower Plant
在线阅读 下载PDF
导出
摘要 UPS不间断电源是保障水电厂计算机监控系统安全、稳定运行的重要设备。因此,介绍思林发电厂计算机监控系统上位机UPS电源改造前在设计和运行中存在的各种问题,提出UPS电源改造设计方案,并对UPS改造过程和优化情况进行详细说明。 UPS is an important equipment to ensure the safe and stable operation of the computer monitoring system in the hydropower plant.This paper introduces the problems existing in the design and operation of the upper computer UPS power supply of the monitoring system in the Silin power plant before the reform,puts forward the design scheme of UPS power supply reform,expounds the process and optimization of UPS reform in detail.
作者 罗晓鸿 LUO Xiao-hong(Silin Power Plant of Guizhou Wujiang Hydropower Development Co.,Ltd.,Tongren 565109,China)
出处 《通信电源技术》 2020年第7期95-98,共4页 Telecom Power Technology
关键词 水电厂 监控系统上位机 UPS 改造 hydroelectric power plant computer monitoring system ups transformreform
作者简介 罗晓鸿(1985-),男,贵州仁怀人,本科,工程师,从事水电厂检修、维护及设备管理等工作。