摘要 HDPE装置干燥机加热管频繁泄漏,制约了装置的运行和发展,通过对泄漏原因进行理论分析,并利用静态强度及动态特性测试进一步探究泄漏机理,明确了造成干燥机泄漏故障的主要因素,为干燥机后续改型提供理论基础与优化方案,顺利解决了泄漏难题。 The frequent leakage of the heating pipe of the dryer in HDPE device restricts the operation and development of the device.Based on the theoretical analysis of the causes of the leakage,the leakage mechanism is further explored by using the static strength and dynamic characteristics test,and the main factors causing the leakage failure of the dryer are identified,which provides the theoretical basis and optimization scheme for the subsequent modification of the dryer,and successfully solves the leakage problem.
作者 葛亚 Ge Ya(Sinopec Yangzi Petrochemical Co.LTD.,Nanjing 210048,Jiangsu,China)
出处 《橡塑技术与装备》 CAS 2020年第8期44-49,共6页 China Rubber/Plastics Technology and Equipment
关键词 HDPE 干燥机 加热管 泄漏 交变应力 HDPE dryer heating pipe leakage alternating stress
作者简介 葛亚(1986-),男,工程师,本科,现从事化工设备管理与现场维护工作。