期刊文献+

原子吸收光谱法测定热障涂层中痕量铁的不确定度分析

Evaluation of Measurement Uncertainty for the Determination of Trace Iron in Thermal Barrier Coatings by AAS
在线阅读 下载PDF
导出
摘要 利用原子吸收光谱法测定热障涂层用红宝石柔性线材中痕量铁。通过建立数学模型,对检测过程中不确定度的主要来源进行分量量化计算,评估痕量铁测定不确定度的主要影响因素,并计算了合成不确定度和扩展不确定度,最终给出热障涂层中痕量铁的检测结果。 Trace iron in Ruby flexible wire for thermal barrier coating was determined by atomic absorption spectrometry.After the determination of trace iron content,a mathematical model was established.The uncertainty for the determination of trace Fe in ruby flexible wire for thermal barrier coating by atomic absorption spectrometry was analyzed.The sources of uncertainty in the measurement process were analyzed.Through the calculation,the main component influence of the uncertainty was evaluated and discussed.It was indicated that the combined standard uncertainty and the expanded uncertainty for the determination of Fe concentration were reported.
作者 李跃龙 张婷 初晓葵 柏霁纹 Li Yuelong;Zhang Ting;Chu Xiaokui;Bai Jiwen(National New Raw Material Construction Engineering Center of Liaoning,Shenyang 110032;National Investigation Police University of China,Shenyang 110035,China)
出处 《广东化工》 CAS 2020年第8期170-171,150,共3页 Guangdong Chemical Industry
关键词 热障涂层 原子吸收光谱 不确定度 Thermal barrier coatings Iron AAS Uncertainty
作者简介 李跃龙(1970-),男,沈阳人,高级工程师,主要研究方向为分析化学;通讯作者:张婷。