期刊文献+

城市轨道交通直流断路器触头烧损情况检测新方法

New Detection Method for the DC Circuit Breaker Contact Burnout of Urban Rail Transit
在线阅读 下载PDF
导出
摘要 直流断路器触头烧损会降低断路器的载流能力,现常采用测量静触头底座至动触头羊角间距离及接触电阻的方法进行触头烧损情况检测。但这些方法不能完全反映触头烧损情况。提出了通过测量触头接触面积来判断触头烧损情况的检测新方法。实践验证结果显示,该方法简单直观、便于操作、准确性较高,可作为触头烧损情况的辅助检测手段。 The burnout of DC circuit breaker contact will reduce the current carrying capacity of circuit breaker.The methods of measuring the distance between the static contact base and the moving contact claw,and the contact resistance are often used to detect the contact burning situation.However,these methods cannot fully reflect the contact burning loss.A new detection method to judge the burning loss of the breaker contact by measuring the contact area is proposed,and the practical verification results show that the method is simple and intuitive,easy to operate with high accuracy.Therefore,it can be adopted as an auxiliary detection method for the contact burnout.
作者 邝志辉 杨晓春 KUANG Zhihui;YANG Xiaochun(Operation Business Headquarters,Guangzhou Metro Group Co.,Ltd.,510380,Guangzhou,China)
出处 《城市轨道交通研究》 北大核心 2020年第5期189-191,共3页 Urban Mass Transit
关键词 城市轨道交通 直流断路器 触头烧损检测 urban rail transit DC circuit breaker contact burnout detection
作者简介 第一作者:邝志辉,工程师。
  • 相关文献

参考文献1

共引文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部