文章介绍并分析了励磁调节器备用通道板卡故障和发电机出口PT慢熔两种情况下励磁系统未正确动作继而引发停机故障的过程、原因及后续处理防范措施。
This paper introduces and analyzes the process,causes and subsequent handling precautions of the shutdown fault of the excitation system caused by the incorrect action of the system in two cases of the excitation regulator's spare channel board fault and generator outlet PT slow-melting.
作者
孙晋志
SUN Jinzhi(Shiliquan Power Plant of Huadian International Power Corporation,Ltd.,Zaozhuang 277103,China)
出处
《电工技术》
2020年第6期106-107,共2页
Electric Engineering
关键词
励磁
故障
通道
逻辑
慢熔
excitation
fault
channel
logic
slow melting
作者简介
孙晋志(1987-),工程师,从事电气检修及相关工程技术管理方面的工作。