摘要
随着配网容量的增大,单相接地故障频发。文章对中性点经ZnO非线性电阻接地系统故障后的零序电流进行小波多尺度分析,通过计算高频分量在固定时间窗内的能量比提出识别判据。最后,结合实际系统继电保护方案及ZnO非线性电阻作用的有效性形成故障识别方法。
Developments in power capacity have made single phase grounding fault increasingly prominent.By using discrete wavelet,the multi-resolution analysis on zero sequence current is performed.According to the high frequency component energy ratio within the time window,the protection strategy based on ZnO nonlinear resistance is put forward.Finally,combined with the effectiveness of the ZnO nonlinear resistance and relay protection scheme in practical system,the ZnO nonlinear resistance grounding mode identification method is designed.
作者
谭王景
刘强锋
王锟
武帆
TAN Wang-jing;LIU Qiang-feng;WANG Kun;WU Fan(Shaanxi Polytechnic Institute,Xianyang,Shannxi,China 712000)
出处
《湖南邮电职业技术学院学报》
2020年第1期14-18,共5页
Journal of Hunan Post and Telecommunication College
基金
2019年陕西工业职业技术学院科研一般项目“ZnO非线性电阻接地方式继电保护策略研究”(项目编号:ZK19-17)。
关键词
弧光接地过电压
氧化锌非线性电阻
小波分析
继电保护
arc grounding overvoltage
ZnO nonlinear resistance
wavelet analysis
relay protection
作者简介
谭王景(1991-),男,陕西渭南人,陕西工业职业技术学院助教,硕士,研究方向:继电保护、故障识别。