期刊文献+

对称零面积梯形成形法削减电荷收集时间效应

Symmetric Zero-Area Trapezoidal Shaping Method Reduces the Effect of Charge Collection Time
在线阅读 下载PDF
导出
摘要 讨论了电荷收集时间对梯形成形效果的影响,统计方法及削减电荷收集时间效应的方法。应用实际测得的梯形脉宽来反推电荷收集时间,所得结果与实际情况符合较好。对60Co放射源进行能谱测试,60Co的两个特征峰的能量分辨率分别为1.9 keV和2.0 keV,验证了幅度提取校正对提高系统能量分辨率的效果。 The effect of charge collection time on the trapezoidal shaping effect,statistical methods and methods to reduce the time effect of charge collection are discussed.The relationship between charge collection time and trapezoidal shaping pulse width is found by theoretical derivation.The calculation formula of charge collection time and the method of amplitude extraction correction are given.The actual trapezoidal pulse width was used to reverse the charge collection time,and the results were found to be in good agreement with the actual situation.The energy spectrum of the 60Co source was tested.The energy resolutions of the two characteristic peaks of 60Co were 1.9 keV and 2.0 keV,respectively,which verified the effect of amplitude extraction correction on improving energy resolution.
作者 邓鹤龄 宫辉 DENG He-ling;GONG Hui(Department of Engineering Physics,Tsinghua University,Beijing 100084,China)
出处 《核电子学与探测技术》 CAS 北大核心 2019年第4期457-462,共6页 Nuclear Electronics & Detection Technology
基金 国家自然科学基金(11475094)资助
关键词 高纯锗 数字多道分析器 电荷收集时间 能量分辨率 对称零面积梯形成形 HPGe digital multi-channel pulse amplitude analysis system charge collection time energy resolution symmetrical zero-area trapezoidal pulse shaper
作者简介 邓鹤龄(1993-),男,湖北孝感人,在读硕士生,攻读方向为数字多道脉冲幅度分析系统研制。
  • 相关文献

参考文献3

二级参考文献10

  • 1肖无云,魏义祥,艾宪芸.数字化多道脉冲幅度分析中的梯形成形算法[J].清华大学学报(自然科学版),2005,45(6):810-812. 被引量:36
  • 2Simoes J B, Correia C. Pulse processing architectures. Nuclear Instruments & Methods in Physics Research Section a-Accelerators Spectrometers Detectors and Associated Equipment, 1999,422(1-3):405-410.
  • 3Impenele C. On nuclear spectrometry pulses digital shaping and processing. Measurement, 2001,30:49-73.
  • 4Cisotti M, et al., Transvereal filter approach of trapezoidal pulse shaping for silicon live targets,Nucl. Instrum. Methods, 1979,159(1):235-242.
  • 5Simoes J B, Correia C M B A. Pulse processing architectures[J]. Nucl Instr and Meth in Phys Research, 1999, A422: 405-410.
  • 6Canberra Industries. Performance of Digital Signal Processors for Gamma Spectrometry[EB/OL]. http: //www.canberra.com, 2004.
  • 7Radeka V. Trapezoidal filtering of signals from large germanium detectors at high rates[J]. Nucl Instr and Meth, 1972, 99: 525-539.
  • 8Cosimo I, Imperiale A. On nuclear spectrometry pulses digital shaping and processing [J]. Measurement, 2001, 30: 49-73.
  • 9Jordanov V T. Real time digital pulse shaper with variable weighting function[J]. Nucl Instr and Meth in Phys Research, 2003, A505: 347-351.
  • 10陈新光,李翔宇,孙义和.粒子探测器读出电路数字滤波器设计[J].电子产品世界,2010,17(10):29-31. 被引量:5

共引文献46