摘要
本文提出了一种针对电压暂降电量损失的评估方法。首先,对电压暂降进行识别,评估暂降特性;然后,分析不同电压暂降条件下用户的停电特性;建立单次电压暂降用户电量损失估算模型;最后,搭建电压暂降引起的电量损失估算模型并结合具体实例进行测算。通过实际案例分析验证了该方法的可行性和准确性。
This paper presents a method to evaluate the loss of voltage dip power.First,the voltage sag is identified and the voltage dip characteristic is evaluated.Then,the power failure characteristics of users under different voltage dip conditions are analyzed.The power loss estimation model of single voltage drop is established.Finally,the power loss estimation model caused by voltage dip is built and the calculation is carried out in combination with specific examples.Finally,the feasibility and accuracy of the method are verified by the actual case analysis.
作者
史帅彬
邓世聪
刘恒勇
张伟
杨梅
Shi Shuaibin;Deng Shicong;Liu Hengyong;Zhang Wei;Yang Mei(Shenzhen Power Supply Co.,Ltd,Shenzhen 518001,Guangdong Province,China;Beijing T&D Power Research Co.,Ltd,Changping District,Beijing 102206 China)
出处
《云南电力技术》
2019年第4期71-73,共3页
Yunnan Electric Power
基金
中国南方电网有限责任公司科技项目(计及电压暂变等关键电能质量因素影响的供电可靠性综合评价体系研究项目)
关键词
电压暂降
电量损失
评估
方法
Voltage dip
power loss
evaluating
method
作者简介