摘要
骨导式助听器属于助听器类的一大分支,由于声音传播路径不同,骨导式助听器电磁兼容性的考察不同于气导式助听器。现行标准中对骨导式助听器的电磁兼容检测方法和指标尚无规定。本文研究了骨导式助听器电磁兼容的要点及检测方法,设计测试流程并对测试结果进行分析,以期对今后的同类产品的质控和检测工作起到技术指导作用。
Bone conduct hearing aids belong to a branch of hearing aids.Because of the different sound transmission paths,the investigation of electromagnetic compatibility of bone-conduct hearing aids is different from that of air-conduct hearing aids.Current standards do not specify the electromagnetic compatibility(EMC)testing methods and acceptance criteria of bone-guided hearing aids.This paper studied the EMC testing methods of bone conduct hearing aids,designed the testing process and analyzed the testing results.
作者
郝烨
李澍
任海萍
HAO Ye;LI Shu;REN Haiping(Division of Active Medical Device and Medical Optics,Institute for Medical Devices Control,National Institutes for Food and Drug Control,Beijing 102629,China)
出处
《中国医疗设备》
2019年第9期27-29,共3页
China Medical Devices
基金
国家重点研发计划(2017YFC0111203)
关键词
骨导式助听器
电磁兼容
医疗设备质控
使用者兼容性
输入相关干扰电平
bone conduct hearing aid
electromagnetic compatibility
medical device quality control
user compatibility
input related interference level
作者简介
郝烨,硕士,主要研究方向为电生理设备及电声设备的质控及评价;通信作者及邮箱:任海萍,renhaiping@nifdc.org.cn