期刊文献+

Beam position monitors as precise phase pickups for beam energy measurement at the Compact Pulsed Hadron Source

Beam position monitors as precise phase pickups for beam energy measurement at the Compact Pulsed Hadron Source
在线阅读 下载PDF
导出
摘要 The 13-MeV proton linac of the Compact Pulsed Hadron Source(CPHS) at Tsinghua University, China,is composed of a 50-keV electron cyclotron resonance proton source, a 3-MeV four-vane-type radio-frequency quadrupole(RFQ) accelerator, and a drift tube linac(DTL). Precise measurement of the beam energies at the exit of the RFQ and the DTL is critical for DTL commissioning. Two button-type beam position monitors(BPMs) installed downstream of the RFQ are used to perform the measurement using a time-of-flight method. The effects of several factors on phase measurement accuracy are analyzed. The phase measurement accuracy of the BPMs at CPHS is better than ± 1.03° at 325 MHz after corrections,corresponding to an energy measurement error of± 0.07%. The beam energy measured at the exit of the RFQ is 2.994 ± 0.0022 MeV,which is consistent with the design value. The 13-MeV proton linac of the Compact Pulsed Hadron Source(CPHS) at Tsinghua University, China,is composed of a 50-keV electron cyclotron resonance proton source, a 3-MeV four-vane-type radio-frequency quadrupole(RFQ) accelerator, and a drift tube linac(DTL). Precise measurement of the beam energies at the exit of the RFQ and the DTL is critical for DTL commissioning. Two button-type beam position monitors(BPMs) installed downstream of the RFQ are used to perform the measurement using a time-of-flight method. The effects of several factors on phase measurement accuracy are analyzed. The phase measurement accuracy of the BPMs at CPHS is better than ± 1.03° at 325 MHz after corrections,corresponding to an energy measurement error of± 0.07%. The beam energy measured at the exit of the RFQ is 2.994 ± 0.0022 MeV,which is consistent with the design value.
出处 《Nuclear Science and Techniques》 SCIE CAS CSCD 2019年第2期1-9,共9页 核技术(英文)
关键词 BEAM energy Time of flight BEAM position MONITOR PHASE PICKUP Beam energy Time of flight Beam position monitor Phase pickup
作者简介 Shu-Xin Zheng ,zhengsx@tsinghua.edu.cn.
  • 相关文献

参考文献1

二级参考文献1

共引文献1

  • 1王忠明,陈伟,邱孟通,闫逸花,张辉,王敏文,王百川,杨业,王迪,刘卧龙,王茂成,吕伟,赵铭彤,赵晨,魏崇阳,王学武,关遐令,郑曙昕,邢庆子,姚红娟,程诚,杜泰斌,张化一,雷钰,王丹,杜畅通,马鹏飞,刘晓宇,李岩,叶文博,于旭东.西安200MeV质子应用装置的建设及调试[J].现代应用物理,2021,12(3):11-24. 被引量:6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部