Fraxion放射治疗定位系统在颅内肿瘤立体定向放射治疗中的临床应用探讨 被引量:6

The clinical application and exploration of Fraxion localization system in SRT for intracranial tumors
在线阅读 下载PDF
导出
摘要 目的:探讨Fraxion放射治疗定位系统的临床应用价值。方法:采用Fraxion放射治疗定位系统对2例颅内肿瘤患者进行体位固定,完成放射治疗计划后在加速器下行位置验证,实施立体定向放射治疗,启动加速器机载锥形束CT(CBCT)程序进行扫描获取治疗部位三维影像,与计划CT影像进行比对。结果:应用Fraxion放射治疗体位固定系统进行颅内的立体定向放射治疗体位固定,患者体位舒适,自动识别和抽吸口腔内的唾液;锥形束CT(CBCT)验证提示,X轴即患者的左右方向线性误差最大值为0.1 cm,均值为(0.08±0.04)cm,旋转角度最大值为0.8°,均值为(0.53±0.30)°,Y轴方向上即患者的头脚方向线性误差最大值为0.3 cm,均值为(0.20±0.06)cm,旋转角度最大值为1.5°,均值为(0.88±0.58)°,Z轴方向即患者的前后方向线性误差最大值为0.1 cm,均值为(0.01±0.04)cm,旋转角度最大值为1.5°,均值为(1.08±0.44)°,三维影像与计划CT影像进行比较,其差异有统计学意义(t=7.00,t=4.92,t=10.18,t=4.25,t=1.90,t=6.91;P<0.05)。结论:应用Fraxion放射治疗体位固定系统进行头部颅内的放射治疗体位固定,能够满足放射治疗靶区的治疗精度和重复性,并可自动识别和抽吸口腔内唾液,保证了治疗安全。 Objective:To investigate the clinical application of the Fraxion localization system in the stereotactic radiotherapy(SRT).Methods:The Fraxion localization system for radiotherapy was used to fix the head position of two patients with intracranial tumors.After the radiotherapy plan was completed,they received position verification under accelerator,and the stereotactic radiotherapy was implemented.And then,CBCT progress that carried on accelerator was started to scan and obtain 3D images about treated position.Finally,the results were compared with planning CT images.Results:The patients with encephalic tumors were comfortable while the Fraxion radiotherapy system for fixed position was used.The oral saliva could be automatically recognized and pumped out.The results of the CBCT showed that the mean of linear error of X-axis(that meant the left-right direction)were 0.08±0.04cm and its biggest was 0.1cm,and the biggest value and mean value of rotation angle was 0.8°and(0.53±0.30)°,respectively.On the Y-axis direction(that meant the head-foot direction of patients),the biggest value and mean of linear error were 0.3cm and(0.20±0.06)cm,and the biggest value and mean of rotation angle were 1.5°and(0.88±0.58)°,respectively.In addition,the biggest value and mean of linear error of Z-axis(that meant the front-back direction of patients)were 0.1cm and(0.01±0.04)cm,respectively,and its biggest value and mean of rotation angle were 1.5°and(1.08±0.44)°,respectively.The difference between 3D images and planned CT images was significant(t=7.00,t=4.92,t=10.18,t=4.25,t=1.90,t=6.91,P<0.05).Conclusion:The application of Fraxion radiotherapy system for fixed position of patients with encephalic tumor can satisfy curative precision and repeatability of target area of radiotherapy,and can automatically identify and pump out oral saliva.Therefore,it can guarantee therapy safety.
作者 郑祖安 肖志平 万正辉 刘飞 钟伟伟 ZHENG Zu-an;XIAO Zhi-ping;WAN Zheng-hui(Department of Oncology,Tongji Hospital,Tongji Medical College,Huazhong University of Science and Technology,Wuhan 430030,China)
出处 《中国医学装备》 2018年第9期43-45,共3页 China Medical Equipment
关键词 放射治疗定位系统 位置验证 治疗安全 立体定向放射治疗 锥形束CT Localization system of radiotherapy Position-check Treatment safety Stereotactic radiotherapy(SRT) Cone beam CT(CBCT)
作者简介 郑祖安,男,(1967-),本科学历,副主任技师,从事放射治疗工作;通信作者:肖志平41436567@qq.com。
  • 相关文献

参考文献13

二级参考文献97

共引文献78

同被引文献64

引证文献6

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部