期刊文献+

高精度磁心损耗测量的比对量热法 被引量:6

Comparison calorimetry method to accurately measure core losses
在线阅读 下载PDF
导出
摘要 针对高效功率变换器中磁心损耗难以测量的问题,本文提出了高频磁心损耗的新测量方法——比对量热法,分析了其基本原理、误差构成以及测量系统实现。通过引入脉宽调制控制的比对电阻作为参考热源,有效提高了测量精度并且改善了传统量热法测量过程的冗长繁琐。实验验证表明,比对量热法能精确测量小损耗角磁性元件的磁心损耗。 Accurate core loss measurements of magnetic components operating at high frequencies are difficult.In this paper,a new method is presented to measure high frequency core loss which is called comparison calorimetry method.The principles,error composition and the measuring system are introduced.By using a comparison resistance which is controlled with pulse width modulation as a reference hot source,this method can effectively eliminate errors of traditional calorimetry,and improve measurement accuracy remarkably.The confirmatory experiment shows that the comparison calorimetry can be used to measure magnetic core loss of the magnetic elements with small loss angle.
作者 汪晶慧 陈开宝 陈为 WANG Jing-hui;CHEN Kai-bao;CHEN Wei(Colleage of Electrical Engineering and Automation,Fuzhou University,Fuzhou 350116,China)
出处 《电工电能新技术》 CSCD 北大核心 2018年第4期83-88,共6页 Advanced Technology of Electrical Engineering and Energy
基金 国家自然科学基金项目(51277032) 福建省自然科学基金项目(2015J01191)
关键词 磁心损耗 量热法 比对量热法 core losses calorimetry comparison calorimetry
作者简介 汪晶慧(1975-),女,江西籍,副教授,博士,研究方向为电力电子高频磁技术;陈开宝(1990-),男,福建籍,硕士研究生,研究方向为电力电子高频磁技术。
  • 相关文献

参考文献2

二级参考文献9

  • 1Brockmeyer A. Experimental evaluation of the influence ofDC premagnetization on the properties of power electronicferrites [A]. APEC [ C]. San Jose,CA, 1996. 1: 454-460.
  • 2Lim M H F, van Wyk J D. Errors in electrical core lossmeasurement for extremely small samples applicable to in-tegrated converters [ A] . APEC [ C]. Washington,DC,2009. 1022-1026.
  • 3Zhang Ju, Skutt Glenn,Lee Fred C. Some practical issuesrelated to core loss measurement using impedance analyzerapproach [A]. APEC [C]. Dallas, 1995. 2: 547-553.
  • 4Mu Mingkai, Li Qiang, David Gilham,et al. New coreloss measurement methods for high frequency magneticmaterials [A]. ECCE [ C]. Atlanta, 2010. 4384-4389.
  • 5Aglen O. Calorimetric measurement of losses in air cooledand water cooled asynchronous motors [ A]. ICEM [ C]. Beijing, 1996. 3 : 256-262.
  • 6Szabados B, Mihalcea A. Design and implementation of acalorimfetric measurement facility for determining losses inelectrical machines [ J ]. IEEE Transactions on Instru-mentation and Measurement, 2002,51 (5) : 902-907.
  • 7Turner D R, Binns K J,Shamsaddeen B N, et al. Accu-rate measurement of induction motor losses using balancecalorimeter [ J ]. IEE roceedings-B,1991,138 ( 5 ):233-242.
  • 8Jalilian A, Gosbell V J, Perera BSP, et al. Doublechamber calorimeter ( DCC) : a new opproach to measureinduction motor harmonic losses [ J ]. IEEE Trans, onEnergy Conversion, 1999,14(3) : 680-685.
  • 9Malliband P D, Carte D R H, Gordon B M. Design of adouble-jacketed, closed type calorimeter for direct meas-urement of motor losses [ A ]. Power Electronics and Var-iable Speed Drives Seventh International Conference[C]. London, 1998. 212-217.

共引文献20

同被引文献26

引证文献6

二级引证文献10