期刊文献+

Study on Separation of Water and Alumina Fine Particles by Cross-Flow Microfiltration 被引量:1

Study on Separation of Water and Alumina Fine Particles by Cross-Flow Microfiltration
在线阅读 下载PDF
导出
摘要 A cross-flow microfiltration process had been developed to separate alumina fine particles from the suspension using a stainless steel membrane tube with a pore size of 10 μm. The influence of cross-flow velocity and trans-membrane pressure on the permeate flux and the solid holdup in permeate had been investigated. It was found that both the permeate flux and the solid holdup in permeate decreased with time. Moreover, the permeate flux increased with an increasing transmembrane pressure but the influence of cross-flow velocity on the permeate flux was quite complex. Both the permeate flux and the solid holdup in permeate in long term filtration had been studied. The operation of cross-flow microfiltration could be carried out stably for 10 hours with the permeate flux values ranging from 520.5 to 936 L/(m^2·h) at rs=1%, while it could continue in 10 hours with the permeate flux values ranging from 226 to 432 L/(m^2·h) at rs=5%. The solid holdup in permeate had been less than 10 mg/L during the whole operating cycle. A cross-flow microfiltration process had been developed to separate alumina fine particles from the suspension using a stainless steel membrane tube with a pore size of 10 μm. The influence of cross-flow velocity and trans-membrane pressure on the permeate flux and the solid holdup in permeate had been investigated. It was found that both the permeate flux and the solid holdup in permeate decreased with time. Moreover, the permeate flux increased with an increasing transmembrane pressure but the influence of cross-flow velocity on the permeate flux was quite complex. Both the permeate flux and the solid holdup in permeate in long term filtration had been studied. The operation of cross-flow microfiltration could be carried out stably for 10 hours with the permeate flux values ranging from 520.5 to 936 L/(m^2·h) at rs=1%, while it could continue in 10 hours with the permeate flux values ranging from 226 to 432 L/(m^2·h) at rs=5%. The solid holdup in permeate had been less than 10 mg/L during the whole operating cycle.
出处 《China Petroleum Processing & Petrochemical Technology》 SCIE CAS 2017年第2期96-103,共8页 中国炼油与石油化工(英文版)
关键词 CROSS-FLOW MICROFILTRATION permeate FLUX REJECTION rate ALUMINA FINE particles cross-flow microfiltration permeate flux rejection rate alumina fine particles
作者简介 Corresponding Author: Prof. Zong Baoning, Telephone: +86-10-82368011; E-mail: zongbn.ripp@sinopec.com.
  • 相关文献

参考文献3

二级参考文献16

共引文献26

同被引文献11

引证文献1

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...