期刊文献+

VU监测网技术设施故障原因分析

Malfunction Cause Analyze of Technology Infrastructures in VHF/UHF Monitoring Network
在线阅读 下载PDF
导出
摘要 固定监测站是VU监测网中最重要的部分,掌握其技术设施故障原因有助于保证VU监测网的正常运行。本文统计了2015~2016年国家无线电监测中心VU监测网固定监测站的维护历史记录,在介绍固定监测站系统组成的基础上,分析导致固定监测站各系统发生故障的原因与对实际监测工作的影响,并提出了未来的升级和改造建议。 Technology infrastructures in fixed monitoring station are the most significant components in VHF/UHF monitoring network,comprehending the reason why its technology infrastructures breakdown are contribute to guarantying the safety of VHF/UHF monitoring network.In this paper,we introduce all the subsystem of fixed monitoring station,analyze the reason that result in malfunctionand how it affect monitoring work by historical maintenance record of VHF/UHF monitoring network of State Radio Monitoring Centre from2015to2016.Asuggestion for upgrading and rebuildingare proposed in the end.
作者 范振雄 武迎兵 Fan Zhenxiong;Wu Yingbing(The Beijing Monitoring Station of State Radio Monitoring Center, Beijing, 100037)
出处 《数字通信世界》 2017年第5期59-62,共4页 Digital Communication World
关键词 VU监测网 技术设施 故障原因分析 升级改造建议 VHF/UHF Monitoring Network Technology Infrastructures Malfunction Cause Analyze Suggestion for Upgrading and Rebuilding
作者简介 范振雄,硕士研究生学历,国家无线电监测中心北京监测站助理工程师,现主要从事无线电监测工作。;武迎兵,硕士研究生学历,国家无线电监测中心北京监测站助理工程师,现主要从事无线电监测工作。