摘要
分别研究了传统反硝化中硝酸盐氮负荷、COD N、pH值对反硝化速率及效率的影响 ,得出传统反硝化时最大硝酸盐氮负荷为 0 .0 8kg (kgMLSS·d) ,合适的COD N为 6~ 7,适宜的pH值为 7.5~ 8。对分别以NO-3 和NO-2 为初始基质的反硝化速率进行的对比试验结果表明 ,在温度为 2 5℃、pH值为 7、基质浓度 <30 0mg L时以NO-2 为初始基质的反硝化速率较快 ,但当基质浓度 >30 0mg L后反而是以NO-3
Study was made respectively on the influences of nitrate nitrogen loading, COD /N ratio and pH value on the rate and efficiency of conventional denitrification. The result showed that in the conventional denitrification, the maximum nitrate nitrogen loading can reach 0.08 kg/(kgMLSS·d) with the proper COD /N ratio of (6~7)∶1 and the optimal pH value of 7.5~8. The comparative study on the denitrification rate by using NO - 3 and NO - 2 as initial substrates indicated that at temperature of 25 ℃, pH value of 7, and substrate concentration < 300 mg/L, more rapid denitrification rate can be achieved based on NO - 2 of substrate; whereas at substrate concentration > 300 mg/L, the denitrification rate is faster based on NO - 3.
出处
《中国给水排水》
CAS
CSCD
北大核心
2002年第9期1-3,共3页
China Water & Wastewater
基金
国家自然科学基金资助项目 (5 98780 4 2 )