期刊文献+

谈燃气锅炉房工程中的电气防爆设计

Electrical Explosion Protection Design of Gas Fired Boiler House
在线阅读 下载PDF
导出
摘要 燃气锅炉房工程施工涉及多方面危险因素,其中一项关键性指标就是防爆。因此,对于燃气锅炉房工程来说,必须对影响其安全的各类要素加以考虑,包括生产、维修等阶段存在的危险因素,在此基础上进行电气防爆设计,最大化减少爆炸事故。论文介绍了引起爆炸的三个基本要素,针对燃气锅炉房工程中的电气防爆设计问题,提出相应的解决措施,以此为设计师提供参考。 The construction of gas boiler house involves many dangerous factors, one of which is explosion proof. Therefore, for the gas boiler house engineering, it is necessary to consider all kinds of factors that affect its safety, including the dangerous factors in productiun, maintenance and other stages, on tile basis of which the electrical explosion proof design should be carried out to maximize the reduction of explosion accidents. This paper introdnces three basic elements that cause explosion, and puts forward the corresponding solving measures in view of the design problem of electric explosion proof in the gas boiler house project, which can be used as a reference for designers.
作者 郭永谦 GUO Yong-qian(Qinghai Special Quipment Inspection lnstitute,Xi'ning 810000,China)
出处 《工程建设与设计》 2018年第17期15-16,共2页 Construction & Design for Engineering
关键词 燃气锅炉房工程 电气防爆设计 措施 gas-fired boiler house engineering electrical explosion-proof design measures
作者简介 郭永谦(1974-),男,山西定裹人,高级工程师,从事热能动力工程与锅炉运行节能研究。