摘要
从BBU池的多点协作传输与动态载波调度关键技术、机房配套和传输光缆配套的建设维护成本、网络稳定性等BBU池部署关键因素分析入手,对BBU池的典型应用场景进行了描述,分别从技术收益分析和接入、汇聚机房的建设方案投资效益进行对比分析,从机房面积、电源负荷需求、光缆需求等多维度分析如何进行BBU池机房选择,提出BBU池部署的应用场景、覆盖范围、池机房选择等具体建设策略。
Beginning with the BBU pool multi-point cooperative transmission and dynamic carrier key technology,supporting and transmission cable supporting the construction of computer maintenance cost,network stability BBU pool deployment,the key factors in the typical application of BBU pool scene is described,respectively from the technical benefit analysis and construction scheme of access,gathering room investment benefit,it compares and analyzes from the room area,the power load demand,cable demand dimensional analysis,such as how to select the BBU pool room,puts forward the concrete construction strategy,such as BBU pool deployment scenarios,coverage,pool room selection.
出处
《邮电设计技术》
2017年第9期35-41,共7页
Designing Techniques of Posts and Telecommunications
关键词
BBU池
网络建设
应用场景
覆盖范围
投资分析
BBUpool
Networkconstruction
Applicationscenarios
Coverage
Investmentanalysis
作者简介
罗清,重庆市信息通信咨询设计院无线网络分院总工,高级工程师,主要从事移动网络规划咨询设计工作;
黄冕,硕士,主要从事移动网络规划咨询设计工作.