摘要
结合XX电厂330 MW机组现场出现的真空度下降和溶氧超标的突发现象,通过分析和现场查找处理,最终确定了问题的症结所在,并成功解决了此问题,为今后同类现象的处理提供了参考价值。
This paper analyzes the phenomenon of sudden decline of vacuum degree and dissolved oxygen site 330MW units exceed the standard XX power plant, and through the analysis of the scene for treatment, and ultimately determine the crux of the problem, and successfully solves the problems and treatment for the similar phenomenon provides a reference value.
出处
《现代工业经济和信息化》
2017年第16期92-93,96,共3页
Modern Industrial Economy and Informationization
关键词
真空度
溶氧
探讨
vacuum degree
dissolved oxygen
discussion
作者简介
吴文祥(1979-),男,毕业于东北电力学院,本科,工程师,研究方向:汽机。