摘要
在介绍可控并联电抗器的技术特点及应用状况的基础上,分析了1 000kV分级式可控并联电抗器的接线与工作原理,并对主要设备参数进行选择,结合实际情况,提出适用于特高压变电站的1 000kV分级式可控并联电抗器布置方案。该方案可控并联电抗器额定容量大,高压侧三相绕组采用星形连接,中性点经小电抗器接地;低压侧三相绕组采用星形连接,中性点直接接地。便于设备选择及降低设备绝缘水平,满足了可靠性、灵活性和经济性的要求。
The paper analyzed the wiring and working principle of the 1 000 kV classifying controllable shunt reactor based on the technical characteristics and application status of the controllable shunt reactor, and selected the main equipment parameters. Proposed for UHV substation of 1 000 kV rated controllable shunt reactor arrangement combined with the actual situation. The scheme of controllable shunt reactor rated capacity is big. high-voltage side-three-phase winding adopts star connection, the neutral point by a small reactor grounding. l.ow-voltage side three-phase windins adopts star connection, neutral point is grounded directly, equipment is easy to choose and reduce equipment insulation level, and meet the requirements of reliability, flexibility and economy.
出处
《吉林电力》
2017年第2期34-36,44,共4页
Jilin Electric Power
作者简介
崔巍(1984),男,工程师,从事变电电气设计工作。