期刊文献+

晶闸管过零关断零电压介质恢复阻断影响因素的分析 被引量:2

Analysis of Zero-Turn-Off Thyristor Zero Voltage Block Media Recovery Influencing Factors
在线阅读 下载PDF
导出
摘要 为了分析晶闸管换流过零的暂态关断恢复特性影响因素,设计了晶闸管强迫过零关断后零电压恢复的试验电路。通过试验系统地研究了影响晶闸管暂态恢复时间的两个重要因素,并且就通流大小、通流时间对晶闸管恢复时间特性具体产生的影响做了详细的分析。分析结果表明,晶闸管通流幅值的增大与通流时间的增长均会对其恢复时间产生不利的影响。 In arder to analyze the factors of transient zero through the thyristor turn-off characteristics of recovery,this paper presented the experimental circuit of thyristor forced through zero-zero-voltage shutdown recovery to study the effects of the thyristor transient recovery time.In respect of factors(the size of the throughflow,flow time) it analyzed the thyristor recovery time characteristics and the impact.The analyais results show that the thyristor through-flow growth and an increase in the magnitude of flow-through time will adversely affect their recovery time.
出处 《电器与能效管理技术》 2017年第6期9-12,共4页 Electrical & Energy Management Technology
基金 国家自然科学基金项目(51207166/51307179) 海军工程大学自然科学基金项目(435517F21)
关键词 晶闸管关断恢复 强迫过零 通流大小 通流时间 off thyristor recovery forced zero crossing size of the through-flow flow time
作者简介 方伟(1990-),男,硕士研究生,研究方向为电力系统及其安全运行。 徐国顺(1969-),男,副教授,研究方询为电力系统自动化与安全运行 王鸣光(1982-),男,工程师,主要从事电力系统保护及其安全运行研究.
  • 相关文献

参考文献16

二级参考文献160

共引文献351

同被引文献23

引证文献2

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部