期刊文献+

一致渗漏供水管网渗漏模型研究 被引量:3

Study on leakage models of water supply network with uniform leakage
在线阅读 下载PDF
导出
摘要 针对一致渗漏供水管网,提出了一致点式渗漏模型,使单点渗漏与整个管网的渗漏水平协调。在同一渗漏水平下,比较了不同渗漏模型和不同压力指数下,管网水力状态的变化。分析表明:节点水压对渗漏模型没有管线流量和渗漏流量那么敏感;渗漏模型中的压力指数对管网水力状态的影响不大。两类渗漏模型对直接连通水源的管线渗漏非常敏感;当直接连通水源的管线渗漏时,管网渗漏将集中到这几根管线上,与管网一致渗漏假定不符。在模拟管网一致渗漏时,需要先排除直接连通水源的管线的渗漏。 In order to simulate the water supply network with uniform leakage, a coordination emitter leakage model was presented to coordinate every emitter loss with the leakage level of entire network. At the same leakage level, the hydraulic performances change of a large water supply network were compared for different leakage models and pressure exponents. The results show that the node pressures are not sensitive to leakage models as the pipe flows and pipe leakage flows. The hydraulic performance is not significantly affected by the pressure exponents in leakag model. Two kinds of leakage models are very sensitive to the pipes directly connected to water sources. If these pipes leak as other pipes of the network, the most part of loss is concentrated in these pipes. It is in consistant with the assumption of uniform leakage of the pipe network. Therefore, it is necessary to eliminate the leakage of the pipes directly connected with sources when we simulate the uniform leakage of a water supply network.
作者 陈玲俐 蔡勇 CHEN Lingli CAI Yong(Department of Civil Enginearing, Shanghai University, Shanghai 200072, Chin)
机构地区 上海大学土木系
出处 《自然灾害学报》 CSCD 北大核心 2016年第5期74-80,共7页 Journal of Natural Disasters
基金 国家自然科学基金面上项目(11272200)~~
关键词 供水管网 一致渗漏 渗漏模型 一致点式渗漏模型 压力指数 water supply network uniform leakage leakage model the coordination emitter leakage model pres-sure exponent
作者简介 陈玲俐(1972-),女,副教授,博士,主要从事生命线工程与建筑结构抗震研究.E—mail:chenll@shu.edu.cn
  • 相关文献

参考文献2

二级参考文献22

  • 1周建华,曲世琳,赵洪宾.配水管网压力与漏水量关系试验研究[J].给水排水,2005,31(8):94-97. 被引量:13
  • 2SMITH L A.Option for Leak and Break detection and Repair for Drink Water Systems.Battelle Press,2000.
  • 3PELLETIER G,MAILHOT A,VILLENEUVE J P.Modeling Water Pipe Breaks-Three Case Studies,Water Resources Planning and Management,2003(3/4):115-123.
  • 4KLEINER Y,RAJANI B.Comprehensive review of structural deterioration of water mains:statistical models,Urban Water,2001(3):151-164.
  • 5RAJANI B,KIEINER Y.Comprehensive review of structural deterioration of water mains:physically based models,Urban Water,2001(3):177-190.
  • 6LASEY K,MAYS L W,TUNG Y K.Relibility and availability analysis of water distribution systems,Water Distribution System Management Handbook.
  • 7O' Rourke M J, Liu X J. Response of buried pipeline subjected to earthquake effects[ M]. MCEER Monograph No. 3, 1999.
  • 8American Lifelines Alliance. Seismic guidelines for water pipelines[S], 2005.
  • 9刘鹤年.流体力学[M].2版.北京:中国建筑工业出版社,2008.
  • 10American Water Works Association. Water audit and leak detection[ M]. AWWA Manual M36, 1999.

共引文献58