摘要 为解决传递对准性能中对准时间和对准精度矛盾的问题,提出了一个传递对准精度评定指标。分析了对准度的涵义,利用对准后导航状态试验数据间接的对传递对准精度进行计算,给出了计算对准度的具体方法和步骤。算例分析结果表明:该指标既能反映对准时间和对准精度,又能反映不同机动对准方案的差异等,可在传递对准方案验证及鉴定相关标准规范的制定中提供参考。 In order to solve the contradictory problems of time alignment and alignment accuracy in the transfer alignment performance, put forward a transfer alignment accuracy evaluation index. Analyzed the meaning of alignment degree, and the accuracy of transfer alignment is calculated by using the data of post navigation state test. The methods and steps of calculation the alignment degree are given. Example analysis results show that the index can reflect the time alignment and alignment accuracy, but also reflect the differences among each maneuver alignment scheme. The index can be in transfer alignment scheme verification and identification of relevant standards formulated to provide the reference.
作者 李文新 闫敦才 潘天峰 桂燕 Li Wenxin Yan Duncai Pan Tianfeng Gui Yan(No. 95997 Unit of PLA, Beijing 100076, China No. 93108 Unit of PLA, Anshan 114001, China)
出处 《兵工自动化》 2016年第10期17-18,30,共3页 Ordnance Industry Automation
关键词 对准度 传递对准 精度评估 惯性导航 alignment degree transfer alignment performance evaluation inertial navigation
作者简介 李文新(1972-),男,河北人,学士,高级讲师,从事军用运输机仪电设备维护保障研究。
  • 相关文献

参考文献5

二级参考文献21

  • 1孟利波,金观昌,姚学锋.DSCM中摄像机光轴与物面不垂直引起的误差分析[J].清华大学学报(自然科学版),2006,46(11):1930-1932. 被引量:25
  • 2Sin J, Lee W, Popa D, et al. Assembled Fourier transform micro-spectrometer[C]. San Jose: Proceedings of the SPIE -The International Society for Optical Engineering, 2006(6109): 610904.
  • 3Dechev, N., W.L. Cleghorn, J.K. Mills. Micro assembly of 3-D microstructures using a compliant, passive micro gripper[J]. Journal of Micro electro mechanical, 2004, 13(2): 176-189.
  • 4Wang Lidai. Development of Automated Robotic Microassembly for Three-Dimensional Mierosystems[D]. Toronto: Department of Mechanical and Industrial Engineering University of Toronto, 2009: 1-3.
  • 5Dechev, N., et al. Development of a 6 degree of freedom robotic micromanipulator for use in 3D MEMS microassembly[C]. Orlando: In Robotics and Automation, 2006. ICRA 2006. Proceedings 2006 IEEE International Conference, 2006: 281-288.
  • 6Montesanti, R.C. Lessons from Building Fusion Ignition Targets with the Precision Robotic Assembly Machine[J].Fusion Science and Technology, 2011(59): 70-77.
  • 7Castro, C. Reconfigurable Assembly Station for Precision Manufacture of Nuclear Fusion Ignition Targets[C]. In ASPE 24th Annual Meeting. 2009: Monterey, CA, United States.
  • 8Tsai Rogery. A versatile camera calibration technique for high accuracy 3D machine vision metrology using off-shelf TV camera and lenses[J]. IEEE Journal of Robotics and Automation, 1987, 3(4): 323-344.
  • 9Zhang, Z. A Flexible new technique for camera calibration[J]. IEEE Transaction on Pattern Anlysis and Machine Intelligence, 2000, 22(11): 1330-1334.
  • 10Wang, Q., et al. Automatic partition focusing based perpendicularity adjustment technology for camera optical axis[C]. In Multimedia Technology (ICMT), 2011 International Conference on. 2011: IEEE.

共引文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部