期刊文献+

电絮凝法处理污水处理厂尾水的研究 被引量:3

Study on Treatment of Wastewater Treatment Plant Tail Water by Electro Coagulation
在线阅读 下载PDF
导出
摘要 电絮凝是一种环境友好型水处理技术,在城市污水处理厂尾水的深度处理上,具有较好的应用前景。为了考察电絮凝法在城市污水处理厂尾水处理方面的处理效果,以氧化沟工艺的出水为处理对象,考察了在不同反应条件下,电絮凝技术对尾水中COD、TN和TP的去除效果。结果表明,电絮凝技术对城市污水处理厂尾水中的各污染物处理效果较为理想,在电极间距为20 mm,电流密度为25 A/m2,电絮凝时间为20 min时,处理效果最佳,对COD、TN、TP、SS及色度的去除率分别达到74.5%、62.3%,73.5%、76.4%和50%,出水能够满足城市杂用水水质标准(GB/T 18920-2002)中冲厕、道路清扫、消防以及绿化等回用要求。 As an environmental friendly technology,electro coagulation application on the advanced treatment of wastewater treatment plant tail water,has good prospects. To improve the treatment efficiency of wastewater treatment plant tail water by electro coagulation method, the electro coagulation process was developed for effluent of oxidation ditch process. The removal efficiency of COD ,total nitrogen, total phosphorus under the different conditions was investigated. The results showed that the removal efficiency of the pollutants by the electro coagulation was very satisfactory. The optimal result was obtained under the conditions of plate spacing of 20 mm, electrolytic time of 20 min and current density of 25 A/m^2. The removal rates of COD, total nitrogen, total phosphorus SS and chroma reached 74.5%, 62.3%, 73.5%, 76.4% and 50% respectively. The water quality by electro coagulation treatment met the standard of Urban miscellaneous water quality (GB/T 18920-2002), can be reused for flushing, cleaning roads, fire and green.
出处 《水处理技术》 CAS CSCD 北大核心 2016年第8期93-95,99,共4页 Technology of Water Treatment
基金 河北省高等学校科学技术研究项目"污水处理厂尾水资源化利用技术的研究"(QN20141209) 河北省高等学校科学技术研究项目"电-Fenton/砂滤组合工艺应用于造纸废水深度处理回用的可行性研究"(Z2015032)
关键词 电絮凝 污水处理厂尾水 深度处理 去除效率 回用 electro coagulation tail water advanced treatment removal efficiency reuse
作者简介 张尊举(1982-),男,硕士研究生,副教授,研究方向为水污染控制与治理技术;电子邮件:zhangzunju@163.com
  • 相关文献

参考文献12

二级参考文献131

共引文献354

同被引文献45

引证文献3

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部