摘要
由于透射式血氧的检测方法受到使用范围限制,因此通过反射式来检测血氧饱和度成了发展的主流。介绍了一种以MSP430F5529为处理器,且基于TI血氧模拟前端芯片AFE4400的反射式脉搏血氧饱和度检测系统的设计方案。通过对比几种基于小波变换的滤波算法的去噪效果,选择最优的滤波算法,以MSP430F5529超微功耗单片机为核心处理器来实现对指尖脉搏信号的采集和降噪的处理。经过实际检验验证样机,基本实现了反射方式对脉搏血氧饱和度的检测功能。
Because of limitation of transmission type oxygen detecting method,using reflective type oxygen instrument to test blood oxygen saturation become main flow of development. Based on TI blood oxygen analog front-end chip AFE4400 and processor MSP430F5529,a design scheme of reflective type pulse oxygen saturation detection system is introduced. In system design process,compare denoising effect of several filtering algorithm based on wavelet transform,select the optimal filtering algorithm,use MSP430F5529 as core processor to complete aquisition of fingerpoint pulse signal and denoising processing. Through practical test,the system prototype machine realizes the function of pulse oxygen saturation detection.
出处
《传感器与微系统》
CSCD
2016年第5期91-93,96,共4页
Transducer and Microsystem Technologies
基金
广西自动检测技术与仪器重点实验室主任基金资助项目(YQ14116)
国家自然科学基金资助项目(61271119)
国家科技支撑计划资助项目(2013BAI03B01)
广西高等学校科学研究项目(KY2015YB096)
作者简介
陈真诚(1965-),男,湖南永州人,教授,主要研究方向为生物传感器与智能仪器。
朱健铭,通讯作者,E-mail:zjmcsu@126.com。