摘要 A method was developed for the simultaneous determination of four kinds of estrogens (hexoestrol, diethylstilbestrol, estrone, and 17-beta-estradiol) in feed by gas chromatography-mass spectrometry (GC-MS). After the sample was extracted by ethyl ether and cleaned-up on HLB phase extraction column, four kinds of estrogens were derived and quantified in gas chromatographymass spectrometry. The results showed that the linear detectable ranged from 2.5 ng· mL-1 to 250 ng· mL-1for hexoestrol and from 5 ng· mL-1 to 500 ng· mL-1 for three other estrogens with the correlation coefficients (R2) were no less than 0.990. The recoveries were in the range of 76.34%-96.33% and the relative standard deviation was no more than 22.7%. The limits of quantitation (LOQ) for all analytics were between 10 ug· kg^-1 and 20 ug· kg^-1. The method was accurate and sensitive and could meet the actual requirements for the analyses of feed samples. A method was developed for the simultaneous determination of four kinds of estrogens (hexoestrol, diethylstilbestrol, estrone, and 17-beta-estradiol) in feed by gas chromatography-mass spectrometry (GC-MS). After the sample was extracted by ethyl ether and cleaned-up on HLB phase extraction column, four kinds of estrogens were derived and quantified in gas chromatographymass spectrometry. The results showed that the linear detectable ranged from 2.5 ng· mL-1 to 250 ng· mL-1for hexoestrol and from 5 ng· mL-1 to 500 ng· mL-1 for three other estrogens with the correlation coefficients (R2) were no less than 0.990. The recoveries were in the range of 76.34%-96.33% and the relative standard deviation was no more than 22.7%. The limits of quantitation (LOQ) for all analytics were between 10 ug· kg^-1 and 20 ug· kg^-1. The method was accurate and sensitive and could meet the actual requirements for the analyses of feed samples.
出处 《Journal of Northeast Agricultural University(English Edition)》 CAS 2016年第1期44-49,共6页 东北农业大学学报(英文版)
基金 Supported by Fund of Harbin Provincial Education Department(2014AB3BN041)
关键词 gas chromatography-mass spectrometry hexoestrol DIETHYLSTILBESTROL ESTRONE 17-beta-estradiol FEED gas chromatography-mass spectrometry, hexoestrol, diethylstilbestrol, estrone, 17-beta-estradiol, feed
作者简介 Huo Feng (1967-), male, Master, senior engineer, engaged in the research of feed and veterinary detection. E-mail: 13845101908@163.com
  • 相关文献

同被引文献94

引证文献6

二级引证文献34

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部