期刊文献+

小型内窥镜干涉型光纤陀螺仪装配质量控制系统(英文) 被引量:2

Development of IFOG assembly quality control system using minitype endoscope
在线阅读 下载PDF
导出
摘要 提出一种用于干涉型光纤陀螺仪(IFOG)装配质量控制的内窥镜系统设计及相关图像分析方法。同时采用1.0mm与2.4mm工业内窥镜系统采集IFOG内部图像与视频数据;并利用多自由度运动控制平台调节内窥镜工作姿态以保证图像的顺利采集。在此基础上,设计了基于db4小波基的图像增强方法,基于灰度共生矩阵的图像纹理特征估计方法以及图像几何形状特征的计算方法等,用以进行内窥镜图像的分析。通过上述系统与方法的应用,能够有效检测出IFOG产品在装配过程中出现的多余物颗粒、光纤断纤或异常胶粘等质量问题,有效提高了IFOG产品的装配质量。 An endoscope system and its corresponding image analysis methods are proposed to implementthe assembly quality control of a kind of Interferometric Fiber Optic Gyroscope (IFOG). Two industrial endoscopes with diameter of 1 mm and 2.4 mm are utilized to capture the inner images and the video of IFOG. Amovement control platform is used to tune the attitude of endoscope system. Some image enhancement methodsand image feature analysis techniques, such as the db4 wavelet enhancement technique, the Gray Level Co-occurrence Matrix (GLCM) feature analysis method and the geometry shape features, etc.employed to improve the imaging output quality of endoscope system. By using the proposed endoscope system, some assembly quality problems such as the remainder particles, the broken fibers, or the improper gluing, etc. can all beobserved and identified conveniently.
出处 《强激光与粒子束》 EI CAS CSCD 北大核心 2016年第6期51-56,共6页 High Power Laser and Particle Beams
基金 supported by National Basic Research Program of China(613186) National Natural Science Foundation of China(61501016)
关键词 IFOG 内窥镜系统 装配质量控制 图像增强 多图像特征 IFOG endoscope system assembly quality control image enhancement multiple image features
作者简介 Liu Haoting (1981- ), male, PhD, engaged in pattern recognition and intelligent system; imkyran@hotmail, com.
  • 相关文献

参考文献3

二级参考文献21

  • 1王鸿南,钟文,汪静,夏德深.图像清晰度评价方法研究[J].中国图象图形学报(A辑),2004,9(7):828-831. 被引量:123
  • 2顾静良,张卫,万敏.基于灰度形态学和邻域熵值的弱小目标检测[J].强激光与粒子束,2004,16(12):1527-1530. 被引量:22
  • 3冯建,周晨波,于文英,许泓彧,董燕.基于灰度共生矩阵的表面粗糙度研究[J].光学与光电技术,2007,5(2):39-41. 被引量:16
  • 4Winder RJ. Morrow PJ. McRitchie IN. et al. Algorithms for digital image processing in diabetic retinopathy[J]. Computerized Medical I maging and Graphics. 2009. 33( 8): 608-622.
  • 5RhaJ.Jonnal R S. Thorn K E. et al. Adaptive optics flood-illumination camera for high speed retinal imaging[J]. Optics Express. 2006. 14(0): 4552-4569.
  • 6Kundur D. Hatzinakos D. Blind image deconvolution[J]. IEEE Signal Processing Magazine. 1996. 13(3): 43-64.
  • 7Dubra A. Sulai Y. NorrisJ L. et al. Noninvasive imaging of the human rod photoreceptor mosaic using a confocal adaptive optics scanning ophthalmoscope] I}, Biomedical Optics Express. 2011. 2(7): 1864-1876.
  • 8Larichev A V. Irochnikov N G. Ivanov P, et al. Deconvolution of color retinal images with wavefront sensing[CJllInternational Symposium on Biomedical Optics. 2001 : 102-116.
  • 9Kingsbury N G. The dual-tree complex wavelet transform: a new technique for shift invariance and directional filters[CJIIProc 8th IEEE DSP Workshop. 1998. 8: 86.
  • 10Kingsbury N. Complex wavelets for shift invariant analysis and filtering of signals[J]. Applied and Computational Harmonic Analysis. 2001. 10(3): 234-253.

共引文献5

同被引文献20

引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部