期刊文献+

^(137)Cs γ射线空气比释动能率的国际关键比对 被引量:1

International Key Comparison of Air Kerma Rate in ^(137)Cs γ Ray
在线阅读 下载PDF
导出
摘要 为建立我国^(137) Csγ射线空气比释动能基准并使之达到国际等效,中国计量科学研究院(NIM)采用石墨空腔电离室在国际计量局(BIPM)^(137) Csγ辐射场中开展了基准装置的直接比对,其比对结果为0.996 7,合成标准不确定度为0.21%。同时采用校准同一电离室的方式开展了间接比对,得到的间接比对结果为0.996 4,合成标准不确定度为0.29%,直接比对和间接比对相对偏差约为3×10-4,在不确定度范围内结果符合较好,该比对结果已进入国际计量局的关键比对数据库。 For the establishment of γ ray air kerma primary standard in 137 Cs and making it achieve the international equivalent, a direct comparison for 1arCs air kerma was car- ried out in the 1arCs radiation field of Bureau International des Poids et Mesures (BIPM) between the National Institute of Metrology (NIM) and BIPM by using a graphite cavity ionization chamber. The comparison result is 0. 996 7 with a combined standard uncertainty of 0.21%. And an indirect comparison was also made using the same chamber calibrated by NIM and BIPM, the result is 0. 996 4 with a combined standard uncertain- ty of 0. 29%. The indirect comparison result is in good agreement with the direct comparison result and the relative error is about 3× 10 4. The results have been presented in BIPM key comparison database finally.
出处 《原子能科学技术》 EI CAS CSCD 北大核心 2016年第2期332-337,共6页 Atomic Energy Science and Technology
关键词 137 CS 空气比释动能 关键比对 不确定度 137Cs air kerma key comparison uncertainty
作者简介 李德红(1980-),男,湖北汉川人,副研究员,博士,从事辐射剂量基准和标准研究
  • 相关文献

参考文献10

  • 1BIPM. FAQ[M/OL]. Paris: BIPM, 2015[2015- 03-25]. http://kcdb, bipm. org/kcdb_faq, asp.
  • 2ALLISY P J, KESSLER C, BURNS D T. Sum- mary of the BIpM. RI(I)-K5 comparison for air kerma in 137Cs gamma radiation[J]. Metrologia, 2013, 50(Suppl. ) : 1-14.
  • 3KESSLER C, BURNS D T, LI D, et al. Key comparison BIPM. RI (I)-K5 of the air kerma standards of the NIM, China, and the BIPM in 137Cs gamma radiation[J]. Metrologia, 2015, 52 (Suppl.) : 6 009 -6 020.
  • 4CCEMRI. Comit6 consultatif pour les 6talons de mesures des rayonnements ionisants constantes physiques pour les 6talons de mesure de rayonne- ment[M]. Paris: BIPM, 1985.
  • 5BURNS D T, ALLISY P J, KESSLER C. Re- evaluation of the BIPM international standard for air kerma in 6Co gamma radiation[J]. Metrolo- gia, 2007, 44(6): 53-56.
  • 6KESSLER C, BURNS D T, ALLISY ROBERTS P J. Re-evaluation of the BIPM international standard for air kerma in 137 Cs gamma radiation [J]. Metrologia, 2009, 46(2): 24-25.
  • 7BOUTILLON M. Volume recombination param- eter in ionization chambers[J]. Phys Med Biol, 1998; 43(8): 2 061-2 072.
  • 8ROGERS D W O, TREURNIET J. Monte Carlo calculated wall and axial non-uniformity correc- tions for primary standards of air kerma[R]. To- ronto, Canada: NRCC, 1999.
  • 9ALLISY-ROBERTS P J, BURNS D T, KESSLER C. Measuring conditions and uncer- tainties for the comparison and calibration of na- tional dosimetric standards at the BIPM [R]. Paris: BIPM, 2011.
  • 10BE M M, CHISTE V, DULIEU C, et al. Table of radionuclides[M]. Paris: BIPM, 2006.