期刊文献+

快速数字影像重建的2维/3维医学图像配准 被引量:12

The 2D/3D medical image registration algorithm based on rapid digital image reconstruction
原文传递
导出
摘要 目的针对2D/3D医学图像配准过程中数字影像重建技术(DRR)生成图像和相似性程度测量两个步骤计算量大、耗时较长这一问题,提出了一种基于Bresenham直线生成算法改进的模式强度与梯度相结合的混合配准算法。方法首先利用Bresenham直线生成算法原理改进传统光线投射算法(Ray-Casting),完成DRR图像的生成;其次模式强度与梯度相结合并引入多分辨率策略来降低相似性测度的计算复杂度;最终利用改进的鲍威尔优化算法对参数进行优化,完成整个配准过程。结果实验结果表明,改进的混合配准算法与基于相关系数、互信息和模式强度的配准算法相比,配准效率大幅提升。模拟配准实验和临床配准实验完成时间分别为76.2 s和64.9 s,比传统配准算法效率提升3 6倍。结论提出的算法在保证配准精度和高鲁棒性的前提下,大幅度地提高了2D/3D医学图像配准算法的运算速度,可以满足临床上精确引导手术进行的实时性要求。 Objective To overcome existing problems in generating digitallg reconstructed radiongrapl (DRR) and to meas- ure the similarity needed for large computations in the process of 2D/3D medical image registration, a hybrid registration al- gorithm was proposed. This algorithm combines pattern intensity with gradient on the basis of the Bresenham line generation algorithm. Method First, the space coordinate system, in which the position of the virtual point light source, 3D volume data, and projection panel can be determined, is established. Second, virtual point light source emits virtual light and the light passes through volume data. The DRR image can be obtained by computing the gray value of points projected by every virtual ray to the image panel via the ray-casting algorithm, which is an enhancement of the Bresenham line generation algo- rithm. Third, the registration components, including interpolator, space transformation component, optimizer, and pyramid filter, are instantiated. The pyramid filter is initialized such that the number of layers and shrinkage factor of each layer are set. Fourth, the reference image and floating image are processed separately into different resolution sequence images andimage pyramids. The image resolution increases from top to bottom in the two pyramids. The arranged images in a pyramid correspond to those of another pyramid. The transformation parameters are calculated by the improved mode intensity meas- ure, and the optimal transformation parameters are obtained by the improved Powell algorithm. The above process will be executed circularly until the image registration is'complete. Result The experimental results show that compared with an al- gorithm based on correlation coefficient, mutual information, and pattern intensity, the proposed method shows a substantial increase in registration efficiency. The completion time of the simulated registration experiment and clinical registration ex- periment are 76. 2 s and 64. 9 s, respectively. The proposed method increases efficiency by 3 ~ 6 times compared with the traditional registration algorithm. Conclusion The hybrid algorithm not only has strong robustness and high clinical require- ment accuracy but also significantly reduces the time required for registration.
出处 《中国图象图形学报》 CSCD 北大核心 2016年第1期69-77,共9页 Journal of Image and Graphics
基金 国家自然科学基金项目(61179019) 内蒙古自治区高等学校科学研究项目(NJZY145) 内蒙古科技大学创新基金项目(2014QDL045)~~
关键词 2D/3D配准 光线投射算法 Bresenham直线生成算法 改进的模式强度 多分辨率策略 改进的鲍威尔算法 2D/3D registration improved Ray-Casting Bresenham line generation algorithm improved pattern intensity(PI) muhi-resolution improved Powell algorithm
作者简介 刘坤(1990-),男,内蒙古科技大学软件工程专业硕士研究生,主要研究方向为医学图像处理。E-mail:liukun19900221@163.com. 通信作者:吕晓琪,博士生导师,E-mail:lxiaoqi@imust.cn
  • 相关文献

参考文献12

二级参考文献109

共引文献57

同被引文献60

引证文献12

二级引证文献46

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部